Henny Penny 342 manual 2-16

Models: 342

1 30
Download 30 pages 50.94 Kb
Page 17
Image 17
2-16.

Model OFE/OFG/OEA/OGA-341, 342

2-16.

BLOWER MOTOR

 

 

REPLACEMENT

 

 

(Continued)

 

 

 

8. Using 3/8 inch nut driver, remove nuts securing blower to the

 

 

unit. Figure 2-48. Pull blower from unit.

 

Figure 2-48

9. Install new blower in reverse order.

2-17.

HEATING ELEMENTS

 

 

(ELECTRIC)

 

 

 

Heating elements are available for 208 and 230 voltage. Check

 

 

data plate to determine correct voltage.

 

Checkout

If the shortening temperature recovery is very slow or at a slower

 

 

rate than required, this may indicate defective heating element(s).

 

 

An ohmmeter quickly indicates if the elements are shorted or open.

 

 

1. Remove electrical power supplied to the frypot to be checked

 

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit

 

 

breaker, or unplug cord at wall receptacle, to the frypot

 

Figure 2-49

to be worked on. Be aware the other control on 2-frypot

 

units will have power.

2.Remove rear cover. Figure 2-49.

3.Using a flat-head screwdriver, remove the appropriate wires from the terminal blocks. Figure 2-50.

Figure 2-50

106

2-17

Page 17
Image 17