REPLACEMENT the airflow is reduced below a set amount, the switch opens and the I/O board cuts power to the gas control valve, which shuts the pilot flame off.
1. Remove electrical power supplied to the unit.
| To avoid electrical shock or property damage, move the |
| power switch to OFF and disconnect main circuit |
Figure | breaker, or unplug cord at wall receptacle. |
2. | Remove the control panel. |
3. | Remove the 2 screws securing the switch to the heat shield. |
| Figure |
4. | Remove the air hose from the air switch. Figure |
Figure |
|
5. | Label and remove wires from air switch. Figure |
6. | Install new vacuum switch in reverse order. |
| To avoid property damage, do not tamper with, or disassemble |
Figure | this component. It is set and sealed from the factory and is not |
to be adjusted. |