Model
To avoid electrical shock, make connections before applying power, take reading, and remove power before removing meter leads. The following checks are performed with the wall circuit breaker closed and the main power switch in the ON position.
| 1. | |
| 2. Using illustrations from previous page, check voltage as | |
| follows: |
|
| Test Points | Results |
| Heat Contactor |
|
| From terminal 34 to 35 | The voltage should read |
| From terminal 35 to 36 | the same at each terminal |
| From terminal 34 to 36 |
|
| Test Points |
|
| Primary Contactor |
|
| From terminal 27 to 28 | It should correspond to the |
| From terminal 28 to 29 | voltage stated on the data |
| From terminal 27 to 29 | plate. |
Replacement | If neither contactor is defective it must be replaced as follows: | |
(Heat Contactor) |
|
|
To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle, to the frypot to be worked on. Be aware the other control on
Figure | 1. Remove only the wires directly connected to the contactor |
being replaced. Label the wires for replacement. Figure |
1003 |