Model OFE/OFG/OEA/OGA-341, 342

2-20. HIGH TEMPERATURE

LIMIT CONTROL (ELECTRIC) (Continued)

4.Pull back cardboard cover and remove the two electrical wires from the high temperature limit control. Figure 2-66.

Figure 2-66

5. Manually reset the control, then check for continuity between

 

the two terminals after resetting the control. If the circuit is

 

open, replace the control, then continue with this procedure.

 

(If the circuit is closed, the high limit is not defective. Re-

 

connect the two electrical wires.)

Replacement

 

 

To avoid electrical shock or property damage, move the

 

power switch to OFF and disconnect main circuit

 

breaker, or unplug cord at wall receptacle, to the frypot

 

to be worked on. Be aware the other control on 2-frypot

 

units will have power.

 

1. Drain the shortening from the frypot.

Figure 2-67

2.Remove capillary from brackets on upper part of element. Figure 2-67.

3.Remove capillary bulb from bulb holder inside the frypot.

Figure 2-68

2-24

1003

Page 24
Image 24
Henny Penny 342 manual High Temperature, Limit Control Electric, Connect the two electrical wires