Model
2-20. HIGH TEMPERATURE
LIMIT CONTROL (ELECTRIC) (Continued)
4.Pull back cardboard cover and remove the two electrical wires from the high temperature limit control. Figure
Figure | 5. Manually reset the control, then check for continuity between |
| the two terminals after resetting the control. If the circuit is |
| open, replace the control, then continue with this procedure. |
| (If the circuit is closed, the high limit is not defective. Re- |
| connect the two electrical wires.) |
Replacement |
|
| To avoid electrical shock or property damage, move the |
| power switch to OFF and disconnect main circuit |
| breaker, or unplug cord at wall receptacle, to the frypot |
| to be worked on. Be aware the other control on |
| units will have power. |
| 1. Drain the shortening from the frypot. |
Figure
2.Remove capillary from brackets on upper part of element. Figure
3.Remove capillary bulb from bulb holder inside the frypot.
Figure
1003 |