REPAIR (Continued)

Henny Penny

Model OE-100

2-16. FILTER PUMP

3. To reassemble, place rotor on drive shaft, and place rollers into

REPAIR (Continued)

rotor.

 

NOTE

 

A small amount of shortening might be needed to hold the

 

bottom roller into place until cover plate is put on. Make sure

 

O-ring is in proper position on plate.

2-17. PUMP REMOVAL

1. If the pump needs to be replaced, loosen one inch nuts from the

 

outflow and inflow lines. Then remove the two bolts holding the

 

pump to the motor with a 1/2 inch wrench.

 

2. The shaft seal should remain on the motor shaft, or if leaking,

 

should be replaced at this time.

 

3. To replace the pump, remove the four allen screws, front plate,

 

rotor, and rollers from pump (see Section 2-18). Place the pump

 

onto shaft and against the shaft seal. Place the two 1/2 inch bolts

 

through the pump and into the motor and tighten. Then replace the

 

rotor, rollers, front plate and tighten the allen screws.

 

When removing a pump from a motor note the positions of

 

the INLET and OUTLET parts. Installation of the pump on

 

the motor in any other position could cause damage to the

 

fryer. There is an indicator on the side of the two halves of

 

the pump, this mark must be together and face to the front

 

of the fryer.