Henny Penny OE-100 fuse, or electrical shock could result, Cooling Fan, Maintenance, Continued

Models: OE-100

1 22
Download 22 pages 7.64 Kb
Page 17
Image 17
fuse, or electrical shock could result.

Henny Penny

 

Model OE-100

2-19. COOLING FAN

5.

Close door and turn power switch on. Unit is now ready for

MAINTENANCE

 

operation.

(Continued)

If the fan needs a more thorough cleaning, or E-4 persists after

 

 

cleaning the fan guard, follow the following steps.

 

1.

With power on, open door to drain pan and look up at fan to

 

 

make sure fan is operating.

 

2.

If fan is not operating, it needs replaced; if fan is operating

 

 

continue onto step 3.

 

3.

Remove electrical power supplied to the unit.

 

 

Place the power switch to the OFF position. Disconnect the

 

 

power cord from the wall, or turn off wall circuit breaker or

 

 

fuse, or electrical shock could result.

 

4.

Remove the screws securing decorative strips on both sides

 

 

of the control, and remove decorative strips.

 

5.

Swing panel out to the left and locate fan on the left behind

 

 

panel.

 

6.

Thoroughly clean fan, plus check fan guard per above in-

 

 

structions.

 

7.

Replace panel and decorative panels.

 

8.

Restore power to unit and unit is now ready for operation.