Henny Penny | Model |
| 1. To replace the pump and motor assembly, insure the main power |
REPLACEMENT | has been removed from the fryer. |
To avoid electrical shock, injury or burns before starting this procedure move COOK/PUMP SWITCH to OFF position. Disconnect main circuit breaker at the main circuit breaker box and unplug service cord from wall receptacle.
2. Remove the cover from the junction box and remove the wire nuts attaching wires leading into the flexible conduit going to the motor.
3. Loosen the two screws securing the flexible conduit going to the motor.
4. Remove tubing to the pump.
5. Remove hardware attaching the motor to the motor hase bracket and remove motor and pump assembly.
| The cooling fan on the |
MAINTENANCE | of heat behind the panel, and if the heat does become excessive, |
| |
| The PC boards on the control panels can be damaged by exces- |
| sive amount of heat so it is important that the cooling fan is |
| operating properly and has good air flow. |
| To prevent an |
| fryer, follow the following steps. |
ONCE A MONTH:
1.Turn power switch to the "OFF" position.
2.Open door to bottom of fryer.
3.Locate metal fan guard situated in the left front, under the control panel.
4.Clean any lint and dirt from fan guard.
294 |