Henny PennyModel
|
| SECTION 2. MAINTENANCE | |
|
|
| |
INTRODUCTION | This section provides procedures for checking and replacement of the | ||
|
| various parts used within the unit. Before replacing any parts, refer to | |
|
| Section 1, Troubleshooting. It will aid you in determining the cause of a | |
|
| particular malfunction. | |
TEST INSTRUMENTS | You may use two test instruments to check the electric compo- | ||
|
| nents. | |
|
| • | A continuity light. |
|
| • | An ohmmeter. |
|
| When the manual refers to the circuit being closed, the continuity | |
|
| light will be illuminated or the ohmmeter should read zero (0) | |
|
| unless otherwise noted. | |
|
| When the manual refers to the circuit being open, the continuity | |
|
| light will not illuminate or the ohmmeter will read one (1). | |
|
|
| NOTE |
|
|
| A continuity light cannot be used to check coils or motors. |
REMOVING THE | To replace parts located inside the fryer, you will need to remove the | ||
| CONTROL PANEL | control panel. The following steps provide the correct procedure. |
1. Place the power switch in the OFF position.
Disconnect the power cord from the wall receptacle or power at the fuse or breaker box, or electrical shock could result.
2. Remove the decorative strip, one located on each side of the control panel, by removing the screw located on the bottom of the decorative strip.
593 |