Henny Penny OE-100 manual Filter Heater

Models: OE-100

1 22
Download 22 pages 7.64 Kb
Page 12
Image 12
2-13. FILTER HEATER

Henny Penny

Model OE-100

2-13. FILTER HEATER

This unit is equipped with a strip heater in the event solidified shorten-

 

ing accumulates in the filter pump lines. If this heater becomes defec-

 

tive, replace by following these steps.

Remove all power from unit. Failure to do so could result in electrical shock.

1.Open panel board and cut wires at the connectors which go to the heaters.

2.Remove two screws that mount the strip heater to insulation box and pull wires through heat shroud.

3.Install new strip heater in reverse order.

NOTE

When installing new heater wires into wire nut, be sure wires are secure. Use electrical tape to secure wire nut.

593

2-12

Page 12