Henny Penny OE-100 manual HIGH TEMPERATURE LIMIT CONTROL Continued, Heating Elements

Models: OE-100

1 22
Download 22 pages 7.64 Kb
Page 5
Image 5
2-5. HIGH TEMPERATURE

Henny Penny

Model OE-100

2-5. HIGH TEMPERATURE

LIMIT CONTROL (Continued)

2-6. HEATING ELEMENTS

15. With excess capillary line pulled out, tighten smaller nut.

NOTE

Tighten nut to snug only. Too tight will damage capillary line.

16.Replace front panel.

17.Refill with shortening.

NOTE

Heating elements are available for 208 and 480 voltage. Check the data plate to determine the correct voltage.

If the shortening's temperature recovery is very slow or at a slower rate than required, this may indicate defective heating element(s). An ohmmeter will quickly indicate if the elements are shorted or open.

1. Remove electrical power supplied to unit.

Place POWER switch in the OFF position and unplug the power cord or open the wall circuit breaker.

2.Remove the control panel. Refer to Section 2-3.

3.Perform an ohm check on one element at a time, with wires disconnected from element. If the resistance is not within tolerance, replace the element.

 

 

Resistance

Voltage

Wattage

in Ohms (Cold)

480

7333

27.5

415

7333

6.9

380

7333

18.8

240

7333

6.9

208

7333

5.6

480

4500

51.2

415

4500

11.75

380

4500

N/A

240

4500

11.75

208

4500

9.61

593