Henny Penny OE-100 Continued, power cord to open the wall circuit breaker, 2-8.FAN, Contactors

Models: OE-100

1 22
Download 22 pages 7.64 Kb
Page 8
Image 8
(Continued)

Henny Penny

 

Model OE-100

2-7. CONTACTORS

The Henny Penny OE-100 requires two switching contactors. Lo-

(Continued)

cated on the bottom is the primary contactor with the heat contactor

 

stacked to the top of the primary. When closed, the primary contactor

 

completes the heat circuit. It also supplies power to the heat contactor.

 

1.

Remove electrical power supplied to the fryer.

 

 

Place ON/OFF switch to the OFF position and unplug the

 

 

power cord to open the wall circuit breaker.

 

2.

Remove the control panel. Refer to Section 2-3.

 

3.

Perform a check on the contactor as follows:

Test Points

Results

from 23 to 29

open circuit

from 24 to 28

open circuit

from 25 to 27

open circuit

from 30 to 34

open circuit

from 31 to 35

open circuit

from 32 to 36

open circuit

from 22 to 26

ohm reading 415

from 33 to 37

ohm reading 415

2-8. FAN

The Henny Penny OE-100 has a fan in the circuit which operates only

 

when the power switch is in the COOK position. The fan helps keep

 

the control panel cool by pulling out heat from between the control

 

panel and frypot.

 

The replacement of a faulty fan is as follows:

To avoid electrical shock or other injury, before starting this procedure, move power switch to OFF position. Disconnect main circuit breaker or unplug cord at receptacle.

1. Remove control panel per Section 2-3.

593

2-8