Image 61
Ethernet Tips

Draft Level—Hitachi Confidential

 

Troubleshooting at the MAC Layer

 

 

alignment errors

Frame that contains a total number of bits not divisible by

 

eight and fails the checksum test. This failure may be a

 

result of collision, a defective NIC, bad cabling, etc.

oversized frames

Frame greater than the maximum Ethernet frame size of

 

1518 bytes. This failure may be caused by jabbering or

 

defective devices in the network. Can cause FIFO buffer

 

overflow, collisions, fragments, CRC, or alignment errors.

FCS errors

Generated when the CRC value on both the sending/

 

receiving stations are not identical. This value is

 

calculated to verify the data integrity of the packet. If the

 

receiving station recalculates the CRC and the value is

 

not the same, the packet is discarded.

dribble bits

As a result of a transmitter (MAC) with poor timing.

Ethernet Tips

Ensure that both port speed and duplexity on the switch and endstations are the same.

By default, autonegotiation is enabled on the switch. If the endstation’s network adapter card is not autonegotiating properly, disable autonegotiation on the switch and manually configure the port settings using the following command:.