Hobart Welding Products 210 MVP manual Electrical Service Guide

Models: 210 MVP

1 56
Download 56 pages 53.5 Kb
Page 23
Image 23

5-7. Electrical Service Guide

Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommendations are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.

 

60 Hz Single Phase

 

 

 

Input Voltage (V)

230 Volts AC

115 Volts AC

 

 

 

Input Amperes (A) At Rated Output

24

 

 

 

 

Max Recommended Standard Fuse Rating In Amperes 1

 

A 20 ampere

Time-Delay Fuses 2

30

individual branch

Normal Operating Fuses 3

 

circuit

35

protected by

 

 

time-delay fuses

Min Input Conductor Size In AWG 4

14

or circuit breaker

 

 

is required.

Max Recommended Input Conductor Length In Feet (Meters)

53

See Section 4-2

(16)

 

 

 

 

Min Grounding Conductor Size In AWG 4

14

 

Reference: 2008 National Electrical Code (NEC) (including article 630)

 

 

1If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.

2“Time-Delay” fuses are UL class “RK5” . See UL 248.

3“Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and above).

4Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table 310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.

5-8. Extension Cord Data (Use Shortest Cord Possible)

.When calculating max. cord length, remember to include conductor length from line disconnect device to input power receptacle.

 

Input Power

 

 

 

Input Voltage

Phase

Hertz

Conductor Size

Max. Cord Length

 

 

 

 

 

115 V

1

60

14 AWG

25 ft (8 m)

 

 

 

 

 

115 V

1

60

12 AWG

55 ft (17 m)

 

 

 

 

 

115 V

1

60

10 AWG

100 ft (30 m)

 

 

 

 

 

230 V

1

60

14 AWG

53 ft (16 m)

 

 

 

 

 

OM-249 498 Page 19

Page 23
Image 23
Hobart Welding Products 210 MVP manual Electrical Service Guide, Extension Cord Data Use Shortest Cord Possible