5-12. Connecting 1-Phase Input Power For 230 VAC Input

1

5

=GND/PE Earth Ground

!

Installation must meet all National

 

and Local Codes − have only

 

qualified

persons

make

this

 

installation.

 

 

!Disconnect and lockout/tagout input power before connecting input conductors from unit.

7

!

Always connect green or green/

 

 

yellow

conductor

to

supply

 

 

grounding terminal first, and never

 

 

to a line

terminal.

 

 

4

 

6

 

L1

1

L2

 

2

3

!Special installation may be required where gasoline or volatile liquids are present − see NEC Ar- ticle 511 or CEC Section 20.

1Black And White Input Conductor (L1 And L2)

2Green Or Green/Yellow Grounding Conductor

3Input Power Cord.

4Disconnect Device (switch shown in the OFF position)

5Disconnect Device Grounding Terminal

6Disconnect Device Line Terminals

Connect green or green/yellow grounding conductor to disconnect device grounding terminal first.

Connect input conductors L1 and L2 to disconnect device line terminals.

7 Over-Current Protection

Select type and size of over-current protection using Section 5-7(fused disconnect switch shown).

8Receptacle (NEMA 6-50R) Customer Supplied

Close and secure door on disconnect device. Remove lockout/tagout device, and place switch in the On position.

8

L2 L1

230 VAC, 1

Tools Needed:

Ref. 250 332-A

OM-249 498 Page 22