Z 1 TYPE THROUGH Z 48 TYPE

This item specifies the zone type for each zone. All choices are listed in this manual under DESCRIPTION OF ZONE TYPES.

For zone types, the current setting is shown on the bottom line.

ZONE 1 TYPE:

 

64

AUXILIARY

#=CHNG

THROUGH

 

 

ZONE 48 TYPE:

 

64

AUXILIARY

#=CHNG

To change a zone type, press the ' # ' key, then use the arrow keys to scroll through the list of zone types. Press the ' # ' key to select a new type. The display shows:

SELECT TYPE:

1

PERIMETER

ZONE RESPONSE TIME

All zones, in the Omni II are set to a 300 millisecond fixed response time.

ZONE TYPES

ZONE TYPE

NUMBER

DESCRIPTION

ENTRY/EXIT

0

Entry/Exit

PERIMETER

1

Perimeter

NIGHT INT

2

Night Interior

AWAY INT

3

Away Interior

2X ENTRY DELAY

4

Double Entry Delay

4X ENTRY DELAY

5

Quadruple Entry Delay

LATCH PERIM

6

Latching Perimeter

LATCH NIGHT INT

7

Latching Night Interior

LATCH AWAY INT

8

Latching Away Interior

PANIC

16

Panic

POLICE EMERG

17

Police Emergency

SILENT DURESS

18

Duress

TAMPER

19

Tamper

LATCH TAMPER

20

Latching Tamper

FIRE

32

Fire

FIRE EMERG

33

Fire Emergency

GAS

34

Gas Alarm

AUX EMERG

48

Auxiliary Emergency

TROUBLE

49

Trouble

FREEZE

54

Freeze

WATER

55

Water

FIRE TAMPER

56

Fire Tamper

AUXILIARY

64

Auxiliary

KEY SWITCH

65

Keyswitch Input

ENERGY SAVER

80

Programmable Energy Saver Module

OUTDOOR TMP

81

Outdoor Temperature

TEMPERATURE

82

Temperature

TEMP ALARM

83

Temperature Alarm

HUMIDITY

84

Humidity

Page 34

Page 40
Image 40
Home Automation 20A00-1 Zone Types, Type Through Z 48 Type, Zone Response Time, Zone Type Number Description