To enable or change a thermostat type, press the ' # ' key. Use the arrow keys to scroll through the list of thermostat types, then press ' # ' to select a new type. The display shows:

 

SELECT TYPE:

1

 

AUTO HEAT/COOL

TYPE

NUMBER

DESCRIPTION

AUTO HEAT/COOL

1

Automatic changeover heat and cool thermostat

HEAT/COOL

2

Manual changeover heat and cool thermostat

HEAT ONLY

3

Heating only thermostat

COOL ONLY

4

Cooling only thermostat

SETPOINT ONLY

5

Setpoint only thermostat

SETUP MISCELLANEOUS

To configure the miscellaneous Installer Setup items, from the Installer Setup menu, press the 6 (MISC) key.

INSTALLER CODE

The Installer code allows the installer access to the Installer Setup menu. The Installer code should be changed and not given to the customer. The Installer code cannot be used for remote phone access.

INSTALLER CODE:

0000-9999 0000=DISABLE

The default setting for the Installer code is 1 1 1 1.

NOTE:

Remember this Installer code and do not disable. There is no way to reset or retrieve the code! If the code is forgotten or disabled, the Omni II controller must be sent back to the factory. Call for an RA#.

ENABLE PC ACCESS

This enables or disables the PC ACCESS feature. Factory default is enabled.

ENABLE PC ACCESS:

1

0=NO 1=YES

PC ACCESS CODE

This code allows dealers to put an access code in the system that is separate from the customer's Master code and the Installer code. Dealers can use the PC Access code to access the system by PC. The PC Access code cannot arm and disarm the system. The PC Access code is NOT programmed from the factory. To use it, set it to any code other than 0000. To disable the PC Access code, enter 0000 for the code.

NOTE: This item must be enabled (by entering a code) if PC Access is will be used.

PC ACCESS CODE:

0000-9999 0000=DISABLE