CONTROLLER OUTPUTS
The Omni II provides 8 programmable hardwired voltage outputs and two horn voltage outputs. These outputs are programmable for the following output types:
•General Purpose low voltage switching applications (12 VDC) - Units 65 - 72
•Sounder triggering (a trigger for siren and voice drivers for BURG and FIRE)
•Communicator outputs (radio, cellular, or any other type of auxiliary communicator)
•'ARMED' and 'OK TO ARM' outputs
•Switched Output (to power smoke detectors and cycle power to latching devices)
Outputs 1 - 8 can supply a maximum of 100 mA each. These outputs are included in the total DEVICES load, which cannot exceed 1A. If the Interior or Exterior Sounder is configured to an Output Type, the HORN outputs can supply a maximum of 1A. HORN outputs are included in the total HORNS load, which can not exceed 1A.
RESET OUTPUTS
Outputs
A
B
FIGURE 8 - RESETTING CONTROLLER OUTPUTS
OUTPUT APPLICATIONS
GENERAL PURPOSE SWITCHING APPLICATIONS
This output will supply 12 VDC to the output terminal when its corresponding unit is ON. Output 1 is designated Unit 65 through Output 8 which is Unit 72. This can be used to drive relays for many different applications, including switching sprinkler valves and
SOUNDER TRIGGERING
This output can be used as a trigger for siren and voice drivers. When a driver requires a separate input for burglary and fire, you can configure this output to give a voltage trigger to the driver. Also, each area can have its own sounder.