OUTPUT TYPES
An output type must be specified for each of the voltage outputs and for the interior and exterior horn outputs. The following output types are available:
OUTPUT TYPE | NUMBER | DESCRIPTION | |
GENERAL PURPOSE | 0 | General Purpose Output | |
OK TO ARM | 1 | OK To Arm | |
ARMED | 2 | Armed | |
3 | |||
INT SNDR | 4 | Interior Sounder | |
INT BURG SNDR | 5 | Interior Burglary Sounder | |
INT FIRE SNDR | 6 | Interior Fire Sounder | |
EXT SNDR | 7 | Exterior Sounder | |
EXT BURG SNDR | 8 | Exterior Burglary Sounder | |
EXT FIRE SNDR | 9 | Exterior Fire Sounder | |
BURG COMM | 10 | Burglary Communicator | |
FIRE COMM | 11 | Fire Communicator | |
AUX COMM | 12 | Auxiliary Communicator | |
SWITCHED POWER | 13 | Switched Power Output | |
A1 | OK TO ARM | 17 | Area 1 OK To Arm |
A1 | ARMED | 18 | Area 1 Armed |
A1 | 19 | Area 1 | |
A1 | INT SNDR | 20 | Area 1 Interior Sounder |
A1 | INT BURG SNDR | 21 | Area 1 Interior Burglary Sounder |
A1 | INT FIRE SNDR | 22 | Area 1 Interior Fire Sounder |
A1 | EXT SNDR | 23 | Area 1 Exterior Sounder |
A1 | EXT BURG SNDR | 24 | Area 1 Exterior Burglary Sounder |
A1 | EXT FIRE SNDR | 25 | Area 1 Exterior Fire Sounder |
A1 | BURG COMM | 26 | Area 1 Burglary Communicator |
A1 | FIRE COMM | 27 | Area 1 Fire Communicator |
A1 | AUX COMM | 28 | Area 1 Auxiliary Communicator |
A1 | SWITCHED POWER | 29 | Area 1 Switched Power Output |
The first group of outputs is global. The sounder and communicator outputs will be activated for an alarm in any area. The remaining types are area specific. Area specific sounder and communicator types will only be activated for alarms in that area. The Setup Control items are:
OUTPUT 1 TYPE: | 0 |
GENERAL PURPOSE #=CHNG ↕ | |
OUTPUT 2 TYPE: | 0 |
GENERAL PURPOSE #=CHNG ↕ | |
OUTPUT 3 TYPE: | 0 |
GENERAL PURPOSE #=CHNG ↕ | |
OUTPUT 4 TYPE: | 0 |
GENERAL PURPOSE #=CHNG ↕ | |
OUTPUT 5 TYPE: | 0 |
GENERAL PURPOSE #=CHNG ↕ | |
OUTPUT 6 TYPE: | 0 |
GENERAL PURPOSE #=CHNG ↕
Page 32