APPENDIX A – CONTACT ID REPORTING FORMAT
ZONE TYPE | TRIP | TROUBLE | DESCRIPTION | |
|
|
|
|
|
Entry/exit (also Double & Quad) | 134 | 370 | Entry/exit burglary | |
Perimeter (also Latching) | 131 | 370 | Perimeter burglary | |
Night Interior (also Latching) | 132 | 370 | Interior burglary | |
Away Interior (also Latching) | 132 | 370 | Interior burglary | |
Panic | 120 | 375 | Panic alarm | |
Police Emergency | 120 | 375 | Panic alarm | |
Silent Duress | 122 | 375 | Silent panic | |
Tamper (also Latching) | 137 | 370 | Tamper burglary | |
Fire | 110 | 373 | Fire alarm | |
Fire Emergency | 110 | 373 | Fire alarm | |
Gas | 151 | 373 | Gas alarm | |
Auxiliary Emergency | 150 | 370 | 24 hour | |
Trouble | 330 | 330 | System peripheral trouble | |
Freeze | 159 | 370 | Low temperature alarm | |
Water | 154 | 370 | Water leakage | |
Auxiliary | none | none | none | |
Fire tamper | 321 | 321 | Bell/siren #1 trouble | |
Temperature Alarm | 152 | 370 | Refrigeration alarm | |
|
|
|
| |
EVENT | CODE | DESCRIPTION |
| |
|
|
|
| |
Zone bypass/restore | 570 | Zone bypass/restore |
| |
Fire zone bypass/restore | 571 | Fire bypass/restore |
| |
Automatic communicator test | 602 | Periodic | test |
|
Cancel | 406 | Cancel |
|
|
User disarm/arm | 401 | Open/close by user |
| |
Programmed disarm/arm | 403 | Automatic open/close |
| |
PC Access disarm/arm | 407 | Remote open/close |
| |
Quick arm | 408 |
| ||
Keyswitch disarm/arm | 409 | Keyswitch open/close |
| |
|
|
| ||
SYSTEM TROUBLE | CODE | DESCRIPTION |
| |
|
|
|
| |
Battery low | 302 | Low system battery |
| |
Fuse | 312 | Power supply overcurrent |
| |
AC power failure | 301 | AC power | loss |
|
Phone line dead | 351 | Phone line #1 trouble |
| |
Digital communicator | 350 | Communication failure |
| |
Fire tamper | 321 | Bell/siren #1 trouble |
|
Page 55