APPENDIX A – CONTACT ID REPORTING FORMAT

ZONE TYPE

TRIP

TROUBLE

DESCRIPTION

 

 

 

 

 

Entry/exit (also Double & Quad)

134

370

Entry/exit burglary

Perimeter (also Latching)

131

370

Perimeter burglary

Night Interior (also Latching)

132

370

Interior burglary

Away Interior (also Latching)

132

370

Interior burglary

Panic

120

375

Panic alarm

Police Emergency

120

375

Panic alarm

Silent Duress

122

375

Silent panic

Tamper (also Latching)

137

370

Tamper burglary

Fire

110

373

Fire alarm

Fire Emergency

110

373

Fire alarm

Gas

151

373

Gas alarm

Auxiliary Emergency

150

370

24 hour non-burglary

Trouble

330

330

System peripheral trouble

Freeze

159

370

Low temperature alarm

Water

154

370

Water leakage

Auxiliary

none

none

none

Fire tamper

321

321

Bell/siren #1 trouble

Temperature Alarm

152

370

Refrigeration alarm

 

 

 

 

EVENT

CODE

DESCRIPTION

 

 

 

 

 

Zone bypass/restore

570

Zone bypass/restore

 

Fire zone bypass/restore

571

Fire bypass/restore

 

Automatic communicator test

602

Periodic

test

 

Cancel

406

Cancel

 

 

User disarm/arm

401

Open/close by user

 

Programmed disarm/arm

403

Automatic open/close

 

PC Access disarm/arm

407

Remote open/close

 

Quick arm

408

Closing-quick arm

 

Keyswitch disarm/arm

409

Keyswitch open/close

 

 

 

 

SYSTEM TROUBLE

CODE

DESCRIPTION

 

 

 

 

 

Battery low

302

Low system battery

 

Fuse

312

Power supply overcurrent

 

AC power failure

301

AC power

loss

 

Phone line dead

351

Phone line #1 trouble

 

Digital communicator

350

Communication failure

 

Fire tamper

321

Bell/siren #1 trouble

 

Page 55

Page 61
Image 61
Home Automation 20A00-1 installation manual Appendix a Contact ID Reporting Format, Zone Type Trip Trouble Description