DATE DISPLAY

This allows you to choose between MONTH/DAY and DAY/MONTH date format.

DATE DISPLAY:

1

1=MMDD

2=DDMM

AC POWER FREQUENCY

 

 

Set this to the appropriate AC Powerline Frequency.

 

AC POWER FREQUENCY:

1

1=60HZ

2=50HZ

DEAD LINE DETECT

NOTE: To disable Omni II from detecting a dead line, set this item to '0'; otherwise adjust only under direction of HAI.

This item adjusts the threshold that is used to determine when the phone line goes dead.

DEAD

LINE DETECT:

8

0-15

0=DISABLE

OFF HOOK DETECT

NOTE: Adjust only under direction of HAI.

This item adjusts the threshold that is used to determine when the phone line is going off hook.

OFF HOOK DETECT:

69

20-250

PICKUP AFTER HANGUP

This item is used to disable Omni II from picking up the phone line after the called party hangs up the line.

PICKUP AFTER HANGUP:

1

0=NO 1=YES

Currently, after the called party or the called party's answering machine hangs up the phone line, Omni II picks up the line and make its "Beep". If you wish to turn the Pickup After Hangup OFF, press 0 then ' # '. To turn it back On, press 1 then ' # '.

The default setting for Pickup After Hangup is Yes.

CLOCK ADJUSTMENT

If the clock on an Omni II is running faster or slower than the actual time, you can have the Omni II automatically compensate up to 29 seconds per day. The Omni II will add or subtract the selected amount of time daily.

CLOCK ADJUSTMENT: 30 1-59=-29 TO +29 SEC/DAY

Enter 1-29 to subtract 1-29 seconds. Enter 31-59 to add 1-29 seconds. Enter 30 for no adjustment to the clock.

The default setting is 30.