HD3MDIH/X EQUIP Series Indoor High Resolution True Day/Night IP Dome Camera User Guide
2.
Note Other fasteners (preferably stainless steel) can be used, provided they are not larger than the screw holes on the mounting template.
Connecting the Wires
Caution Installation must be performed by a qualified electrician. The power wire size for the distance and the number of cameras must be determined to maintain 24 VAC at each camera.
Connecting Audio and Alarms
1.Pull the wires through the ceiling or wall hole until you have at least 4 inches of wire.
2.Remove the green connector strip (see Figure
3.Connect a twisted pair (UTP) cable from each peripheral alarm contact to each alarm input on the terminal block, as shown in Figure
Figure
Power | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Table
PIN Definition
1Audio In +
2Audio In -
3Audio Out +
4Audio Out -
5Alarm In +
6Alarm In -
7Alarm Out +
8Alarm Out -
Document | 19 |
12/10 |
|