converters) transfers power to the mobile device internal charging circuitry which, in turn, recharges the main battery and backup battery.
Note: Once you receive the Low Battery Warning, you have approximately 5 minutes to perform an orderly shutdown and replace the main battery before the unit powers off. The Low Battery Warning will transition to Critical Suspend before the MX3Plus powers off.
Critical Suspend StateThe Critical Suspend state or mode can only be entered because of a main battery Power failure. A main battery Power failure can occur because the battery’s energy has been depleted or the battery has been removed.
When the mobile device is in the Critical Suspend state the main battery LED illuminates, the System LED blinks red, all peripherals are shut down, the CPU clock is stopped, and power is removed from the PCMCIA cards.
The operating system is saving the state prior to the backup battery failing and cannot be used. If a new fully charged main battery is installed before the backup battery fully depletes the operating system will transition to the Suspend state. To resume operation tap the Power key.
Backup BatteryThe MX3Plus has a backup battery that is designed to provide
It takes several hours of operation before the backup battery is capable of supporting the operation of the MX3Plus. The duration of backup battery life is dependent upon operation of the MX3Plus, it’s features and any operating applications. The backup battery is replaced by qualified service personnel.
Note: An uninterrupted external power source (wall AC adapters or DC/DC converters) transfers power to the MX3Plus’s internal charging circuitry which, in turn, recharges the main battery and backup battery.
Backup Battery MaintenanceNote: Make sure there is a fully charged main battery in the MX3Plus before running the backup battery Discharge Utility. The backup battery can be discharged and charged while the MX3Plus is receiving external power through the Power Jack or from a powered cradle.
The NiCd backup battery should be discharged completely once or twice a year. The main battery will fully charge the backup battery. This process will allow longer life for the backup battery.
The backup battery is discharged by selecting Start > Settings > Control Panel > Battery and tapping the “Discharge” button. The discharge utility shows the progress of the discharging. At this time, the program can be exited while continuing the discharge process. Normal use of the MX3Plus can resume during the discharge, with the exception of
DO NOT REMOVE THE MAIN BATTERY from the MX3Plus until the backup battery is completely discharged – in approximately 1 hour and recharged in approximately 2.5 hours.