CONDUIT (INCH)

3/4

1

SIZE

EMT

 

 

CONTROLLER WIRE

 

 

 

MAX DISTANCE (FT)

150

200

 

 

 

TURBINE TO

TURBINE WIRE

#10 (#6 GND)

#8 (#4 GND)

 

 

 

 

TURBINE POLES

 

 

AC IN

 

 

 

L1 N GND

AC INPUT FROM MAIN SWITCH BOARD SINGLE PHASE 120V 15AMP

 

 

 

 

 

 

 

 

 

(2) #12 THWN-2

+ #6 GND ¾” CONDUIT

 

 

 

 

 

 

 

 

 

 

 

L1 N GND

AC OUTPUT TO SUB SWITCH BOARD SINGLE PHASE 120V 15AMP

 

 

 

 

 

 

 

 

 

(2) #12 THWN-2

+ #6 GND ¾” CONDUIT

 

 

 

 

 

 

Controller

 

 

 

 

 

 

 

 

 

 

 

SMARTBOX™

 

 

 

CAT5E or CAT6

 

 

 

 

 

 

 

 

 

 

G O R

 

 

 

 

 

 

 

TURBINE

T

G/W OHR

GND#4+2-THWN#4(2) CONDUIT1” FEET.6DISTANCEMAX

 

 

 

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HT

BLU/W

 

 

 

 

 

 

 

 

 

 

BRN

 

 

 

 

 

 

 

 

HT

BRN/W

 

 

 

 

 

 

 

 

 

 

N GR

 

 

 

 

 

 

 

 

HT

 

N/ WGR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12V

12V

OPTIONAL

 

 

 

 

 

 

 

 

 

12V

12V

 

 

 

 

 

 

 

 

 

 

12V

12V

 

 

 

 

 

 

 

 

#6 GND

FEET.

 

 

 

 

 

 

 

 

 

 

(2) #10 THWN-2 + ¾” CONDUIT MAX DISTANCE 3

 

 

 

 

 

 

 

 

ORG

 

 

 

 

 

 

 

 

 

 

HT

ORG/W

 

 

 

 

 

 

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

 

HT

BLU/W

 

 

 

 

 

 

GND

 

 

 

 

BRN

 

 

 

 

 

 

 

 

 

T /W HBRN

 

 

 

 

 

 

#4

 

 

 

 

GRN

 

 

 

 

 

 

EARTH GROUND STAKE

BOXJUNCTIONTURBINE

 

 

 

 

 

SIZECONTROLLERTOTURBINESEE

1SHEETONCHART

 

 

 

 

HT

GRN/W

 

 

 

 

 

 

 

 

 

Figure 2.4

Wiring Diagram