Specifications

38

 

 

 

 

Non Grid-Tie Smart Box Electrical Specifications

Description

Rating

Units

Input

 

 

Maximum Turbine Voltage

200

Volts DC

Operating input voltage range

30-170

Volts DC

Maximum input current

18

Amps DC

Maximum input short circuit current

20

Amps DC

 

 

 

Inverter

 

 

Operating voltage range

120VAC+/-3%

Volts AC

Operating frequency range or single frequency

60Hz+/-0.05%

Hz

Nominal output voltage (ac)

120

Volts AC

Nominal output frequency

60

Hz

Maximum continuous output current

12.5

Amps AC

Maximum continuous output power (ac)

1500

VA

Maximum output fault current (ac) for 3 minutes

14.5A / 3 min

Amps AC

Maximum output overcurrent protection (ac)

20

Amps AC

 

 

 

Charge

 

 

Nominal output voltage (dc)

24

Volts DC

 

 

 

Charger output voltage operation range (dc)

12-30

Volts DC

Maximum continuous output current (dc)

60

Amps DC

Maximum continuous output power (dc)

1500

Watts DC

Maximum output current (dc)

60

Amps DC

Maximum output fault current (dc)

62

Amps DC

Environment

60

Hz +/- 0.05%

Normal operation temperature range

0 - 40

Deg C

Storage temperature range

-30 - 70

Deg C

 

 

 

Other

 

 

GFI Trip

0.5

Amps

Operating Power

<3.5

Watts

Output Waveform

Pure Sine

THD > 3%

Inverter Efficiency

94.00%

 

Changer Efficiency

>90%

 

Charger regulation method

Three Stage: bulk, absorption, float

 

Manufacturer reserves the right, without notice or liability, to change design and specifications at any time.

DATA SUBJECT TO CHANGE WITHOUT NOTICE

SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14

Page 45
Image 45
Honeywell WT6500 owner manual Non Grid-Tie Smart Box Electrical Specifications, Input, Charge, Environment, Other