Operation

30

 

 

 

 

the energy consumption state (see the Fault and Troubleshooting section for complete details):

Display- Display State

Description

TURBINE FAULT

Turbine is stopped and contains a GFI fault.

GFI

 

TURBINE FAULT

Voltage sensed but Anemometer not sensing wind

NO WIND SPEED

speed.

TURBINE FAULT

Turbine is stopped and contains an over current fault.

TURBINE OVER CURRENT

TURBINE FAULT

Turbine is stopped and contains an over temperature

TURBINE OVER VOLTAGE

fault.

TURBINE FAULT

Anemometer is sensing wind speed but there is no

NO TURBINE

voltage sensed.

TURBINE FAULT

Turbine is stopped and contains a low battery fault.

LOW BATT

 

TURBINE FAULT

Turbine is stopped and contains a high battery fault.

HIGH BATT

 

TURBINE FAULT

Turbine is stopped and contains an over temperature

OVER TEMP

fault.

TURBINE FAULT

Turbine is stopped and contains an over current fault.

CHARGE OVER CURRENT

 

 

 

TURBINE FAULT

See Figure 4.4

INVERTER NO OUTPUT

 

 

 

TURBINE FAULT

 

INVERTER OVER

See Figure 4.4

CURRENT

 

Figure 4.3 Turbine Fault Stop States

Turbine User Stop State

The turbine will enter its User Stop state if the user engages the manual stop command in the technician’s menu accessible via the SMARTBOX™ Controller. When the SMARTBOX™ Controller is in user mode, the turbine is immediately stopped. While in user stop mode, no A/C will be produced so the inverter is shut off and the transfer switch is switched back to the grid. The SMARTBOX™ Controller must be placed in run mode before a charge cycle can start again.

Display - Stopped State

Description

TURBINE STOPPED

Turbine is stopped with no faults. Back light is off with

PRESS ANY KEY

no information scroll.

System Protection

Cool Down

The turbine will shut off and begin cool down if the charger reaches or exceeds a temperature of 125°c or/and the enclosure reaches or exceeds a temperature of 60°c. The turbine will resume working after the charger temperature drops below 70°c and/ or the enclosure temperature drops below 45°c.

Over Wind Speed

The turbine will turn off when wind speed reaches 42mph or higher. It will resume working after the wind speed drops to 35mph or lower.

SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14

Page 37
Image 37