Operation

34

 

 

 

 

View Data Menu

1

.VIEW-TURBINE INPUT

V=100 I=4 P=400

UP/DWN

2

.VIEW-BATTERY CHARGE

 

V=27.2 I=2 P=54.4

3

UP/DWN

.VIEW-INVERTER V=27.2 I=0 P=0

4

UP/DWN

UP/DWN

.VIEW-AC OUTPUT V=120 I=0 P=0

UP/DWN

5

.VIEW-ENVIRONMENT

ws=5 wd=16

UP/DWN

6

.VIEW-TEMPERATURE

Te=30 Tc=35 Ti=0

7

UP/DWN

.VIEW-WS POWER ws=10 P=400 E=34

Figure 4.7 View Data Menu

1.Turbine Input. This screen shows the turbine output voltage (VDC), current (amps) and power (W).

2.Battery charge. This screen shows the voltage (VDC), current (amps) and power (W) being applied to the batteries.

3.Inverter. This screen shows the voltage (VDC), current (amps) and power (W) being applied to the inverter.

4.AC Output. This screen shows the output voltage (VDC), current (amps) and power

(W) of the inverter.

5.Environment. This screen shows the current wind speed (ws) and wind direction (wd). The wind speed is in mph and wind direction is in degrees.

6.Temperature. This screen shows enclosure temperature (Te), charger temperature (Tc) and external temperature (Ti). Temperature external is reserved for future use and may display 0. All temperatures are in Celsius.

7.WS Power. This screen shows wind speed (ws) in MPH, power (P) in W and total energy (E) in watt-hours.

SMARTBOX™ Controller for HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev14

Page 41
Image 41
Honeywell WT6500 owner manual View Data Menu