Controller Energy Consumption States

Display On State

The Display state is enabled by pressing any key on the SMARTBOX™ Controller. This state will enable the LCD backlight and cause user information to scroll on the second line of the LCD screen. This state is also active when accessing the menus. If no buttons are pressed, the SMARTBOX™ Controller will automatically switch back to the running state.

Display Off State

The off state is the default state if the turbine is producing energy from the wind, waiting for the wind, or if any button on the system controller is pressed. The display backlight will be off and no information will scroll. If any faults occur in this state, the fault will be displayed. The controller will maintain this state if the turbine input voltage is greater than 20VDC.

Turbine Operating States

Turbine Running State

When the turbine is in its running state, the following will be shown on the display and is based on the energy consumption state:

Display - Main Menu Scroll

Description

 

 

CHARGER:

Displays the charger operating state:

BULK

Charge is in bulk charge stage

ABSORPTION

Battery is in absorption stage

FLOAT/READY

Battery charge cycle complete and ready for use

STOPPED

Charge cycle has stopped

FAULT

Reference Fault Table on page 37, Figure 4.3

TURBINE:

Displays the turbine operating state:

STOPPED

Stopped State

RUN NO WIND

Turbine is running but no wind is present

RUN WIND

Turbine is running and wind is present

FAULT STOP

Reference Fault Table on page 37, Figure 4.3

AC:

Displays the transfer switch location:

GRID

AC output is connected to grid

AC TURBINE

AC output is connected to turbine inverter

FAULT

Reference Fault Table on page 37, Figure 4.3

POWER

Displays the power generated by the turbine

PRODUCTION

Displays the total accumulated energy generated by

 

the inverter from batteries

WIND SPEED

Displays measured wind speed

 

 

 

 

Display - Display Off

Description

TURBINE RUNNING

Turbine is running with no faults. Back light is off

PRESS ANY KEY

with no information scroll.

Figure 4.2 Turbine Running States

Turbine Fault Stop State

The turbine will enter its Fault Stop state if any faults occur. The turbine will stop operating and the user must clear the faults to restart the turbine. The faults are cleared by pressing ENTER on the SMARTBOX™ Controller control panel. The following will be shown on the SMARTBOX™ Controller LCD screen and is based on