Hoshizaki HWR40A(-D) f Temperature Display Scale F5, g Alarm History F6, Alarm Code, Description

Models: HWR68A(-D) HUR40A(-D) HUR68A(-D) HUR96A(-D) HWR40A(-D)

1 64
Download 64 pages 59.88 Kb
Page 30
Image 30

4)Press the f)Temperature Display Scale (F5) unmarked, blank button to save the setting.

5)Press the MANUAL DEFROST button to return to the menu screen. Press and hold

both the g)Alarm History (F6) button and the Alarm Code unmarked, blank button for 5 seconds to exit the setting mode and return to the temperature display.

6)If a jumper was present between connector K151 pins 7 and 8, reconnect it after all setting and diagnostic work is complete.

f)Temperature Display Scale (F5)

For information about switching the display between °F and °C, see "D.2.a) Switching the Display Between Fahrenheit and Celsius (F5)."

g)Alarm History (F6)

To view the alarm history, follow the steps below.

1)Make sure the jumper is removed between connector K151 pins 7 and 8 on the control board. Otherwise you will not be able to access this setting. For details, see "D.1. Gaining Access to Settings and Diagnostics."

2)Press and hold both the Description button and the Manual background unmarked, blank button for 5 seconds. "F0" should appear in the display window. Press the MANUAL DEFROST button until "F6" appears in the display window.

3)Press the Manual background unmarked, blank button to display the alarm history. The alarms will be displayed in reverse chronological order (newest to oldest - up to 8 alarms). When "--" is displayed, you have reached the end of the alarm history and the display will begin again.

Note: The alarms are as follows:

Alarm Code

Description

E1

High Temperature Alarm

E2

Low Temperature Alarm

E3

Defrost Alarm

E4

High Pressure Alarm

 

 

E7

Clogged Filter Alarm

 

 

E8

Defrost Temperature Sensor Malfunction Alarm

E9

Clogged Filter Sensor Malfunction Alarm

EA

EEPROM Write Error Alarm

ED

EEPROM Verification or Read Error Alarm

4)To reset the alarm history, press and hold both the Manual background unmarked, blank button and the MANUAL DEFROST button for 5 seconds.

5)Press the MANUAL DEFROST button to return to the menu screen. Press and hold

both the Manual background button and the Manual background unmarked, blank button for 5 seconds to exit the setting mode and return to the temperature display.

6)If a jumper was present between connector K151 pins 7 and 8, reconnect it after all setting and diagnostic work is complete.

30

Page 30
Image 30
Hoshizaki HWR40A(-D), HUR96A(-D), HUR68A(-D) f Temperature Display Scale F5, g Alarm History F6, Alarm Code, Description