Hoshizaki HUR40A(-D), HWR40A(-D), HUR96A(-D), HUR68A(-D), HWR68A(-D) Problem, Possible Cause, Remedy

Models: HWR68A(-D) HUR40A(-D) HUR68A(-D) HUR96A(-D) HWR40A(-D)

1 64
Download 64 pages 59.88 Kb
Page 43
Image 43

Problem

Possible Cause

 

Remedy

[5]

Cabinet

a)Setpoint and/or

1. Incorrect.

1. Correct setting(s).

 

temperature too

Differential

 

See sections "II.D.2.b)" and

 

high.

 

 

"II.D.3.c)" for defaults.

 

 

b)Door

1. Not sealing, opened

1. Check for sealing, check for

 

 

 

frequently or open for

door open at time of warm

 

 

 

long intervals.

cabinet temperature.

 

 

c) Defrost

1. Defrost time

1. See "[8] Evaporator does

 

 

 

insufficient to remove

not defrost completely."

 

 

 

frost.

 

 

 

 

Operation in humid

 

 

 

 

conditions.

 

 

 

d)Refrigerant

1. Leak.

1. Repair leak and recharge.

 

 

e)Fan Motor

1. Defective.

1. Check and replace.

 

 

f) Air Filter

1. Clogged.

1. Clean.

 

 

g)Condenser

1. Dirty.

1. Clean.

 

 

h)Thermistor

1. Defective.

1. Check and replace.

 

 

 

 

 

 

 

i) Control Board

1. Defective.

1. Replace.

 

 

j) Outside Heat Source

1. Too close to unit.

1. Separate unit from heat

 

 

 

 

source.

 

 

k) Air Flow

1. Blockage inside

1. Remove blocakge by removing

 

 

 

interior.

or redistributing food product.

 

 

l) Warm Food

1. Warm food recently

1. Allow time for unit to return to

 

 

 

placed in refrigerator.

setpoint temperature.

[6]

Cabinet

a)Power Supply

1. "OFF" position.

1. Move to "ON" position.

 

temperature

 

2. Loose connection(s).

2. Tighten or reconnect.

 

display

 

 

 

 

 

3. Failure or tripped

3. Call electrician and/or reset

 

indicator does

 

 

 

breaker.

breaker.

 

not illuminate

 

 

b)Control Board

1. Defective.

1. Replace.

 

properly.

 

 

 

 

[7]

Cabinet

a)Setpoint and/or

1. Incorrect.

1. Correct setting(s).

 

temperature too

Differential

 

See sections "II.D.2.b)" and

 

low.

 

 

"II.D.3.c)" for defaults.

 

 

b)Frozen Food

1. Frozen food recently

1. Allow time for unit to return to

 

 

 

placed in refrigerator.

setpoint temperature.

 

 

c) Thermistor

1. Defective.

1. Check and replace.

 

 

d)Compressor Relay

1. Defective; contacts

1. Replace.

 

 

 

welded.

 

 

 

e)Control Board

1. Defective.

1. Replace.

[8]

Evaporator does

a)Defrost Thermistor

1. Defective.

1. Check and replace.

 

not defrost

b)Defrost

1. Not enough defrosts

1. Factory default is once every

 

completely.

 

occurring per day.

6 hours. If coil is frosting too

 

 

 

Operation in humid

much, can shorten defrost

 

 

 

conditions.

interval.

 

 

c) Defrost Heaters

1. Defective.

1. Replace heaters.

 

 

d)Safety Defrost

1. Defective, turning off

1. Replace safety defrost

 

 

Thermostat

heaters prematurely,

thermostat.

 

 

 

or fused open.

 

 

 

e)Defrost Heater

1. Blown.

1. Determine why fuse blew.

 

 

Temperature Fuse

 

Replace fuse.

43

Page 43
Image 43
Hoshizaki HUR40A(-D), HWR40A(-D), HUR96A(-D), HUR68A(-D), HWR68A(-D) service manual Problem, Possible Cause, Remedy