Hoshizaki KM-630MRH, KM-630MWH, KM-630MAH service manual 2nd Cycle and after with pump drain

Models: KM-630MAH KM-630MRH KM-630MWH

1 67
Download 67 pages 19.6 Kb
Page 19
Image 19
2nd Cycle and after with pump drain

2nd Cycle and after with pump drain

IMPORTANT

Freeze cycle time is limited to 60 minutes even if Float Switch does not open.

1.Float Switch opens and signals to complete freeze cycle.

Drain timer starts counting.

2.Drain timer stops counting. Pump drain is completed

3.Thermistor reads 48° F. Defrost Timer starts counting.

Manual background&

5.After the first 5 minutes in freeze cycle. Ready to complete freeze cycle when Float Switch circuit opens.

IMPORTANT

Board never accepts freeze completion signal within the first 5 minutes in freeze cycle.

IMPORTANT Water Valve opening is limited to 6 minutes.

4.Defrost Timer stops counting.

Defrost cycle is completed and freeze cycle starts.

IMPORTANT

1.Board never accepts defrost completion signal within the first 2 minutes in defrost cycle.

2.Defrost cycle time is limited to 20 minutes even if Defrost Timer does not stop counting.

19

Page 19
Image 19
Hoshizaki KM-630MRH, KM-630MWH, KM-630MAH service manual 2nd Cycle and after with pump drain