Hoshizaki KM-630MWH, KM-630MRH, KM-630MAH service manual b SANITIZING PROCEDURE

Models: KM-630MAH KM-630MRH KM-630MWH

1 67
Download 67 pages 19.6 Kb
Page 66
Image 66

[b] SANITIZING PROCEDURE

Following Cleaning Procedure

1)Dilute a 5.25 % Sodium Hypochlorite solution with water (Add 1.5 fl. oz. of sanitizer to 3 gal. of water).

2)Remove the Insulation Panel, if it is in its usual position.

3)Pour the sanitizing solution into the Water Tank.

4)Replace the Insulation Panel and the Front Panel in their correct positions.

Note: Make sure that the Control Switch is in the “WASH” position and the Cleaning Valve is open.

5)Turn on the power supply, and start the sanitizing process.

6)Turn off the power supply after 15 minutes.

7)Remove the Front Panel and if necessary, the Insulation Panel.

8)Drain the Water Tank. See the above step 5) in “[a] CLEANING PROCEDURE.”

9)Replace the removed parts and the Insulation Panel in their correct position.

10)Repeat the above steps 17) through 29) in “[a] CLEANING PROCEDURE” two times to rinse thoroughly.

11)Close the Cleaning Valve.

12)Move the Control Switch to the “ICE” position.

13)Replace the Front Panel in its correct position.

14)Clean the Storage Bin with water.

15)Turn on the power supply, and start the automatic icemaking process.

66

Page 66
Image 66
Hoshizaki KM-630MWH, KM-630MRH, KM-630MAH service manual b SANITIZING PROCEDURE