Hoshizaki KM-630MRH, KM-630MWH service manual Performance Data, a KM-630MAH, 1250, 1332

Models: KM-630MAH KM-630MRH KM-630MWH

1 67
Download 67 pages 19.6 Kb
Page 37
Image 37

4.PERFORMANCE DATA

[a] KM-630MAH

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

 

600

272

 

562

255

 

514

233

 

 

 

 

80/27

 

571

259

 

512

232

 

466

211

lbs./day

 

kg./day

 

90/32

 

562

255

 

470

213

 

422

191

 

100/38

 

554

251

 

459

208

 

378

171

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

 

1250

 

 

1274

 

 

1297

CONSUMPTION

80/27

 

 

1268

 

 

1305

 

 

1323

 

 

 

 

90/32

 

 

1274

 

 

1332

 

 

1352

watts

 

 

 

100/38

 

 

1275

 

 

1336

 

 

1370

APPROXIMATE WATER

70/21

 

341

1.29

 

287

1.09

 

253

0.96

CONSUMPTION PER 24 HR.

80/27

 

300

1.14

 

216

0.82

 

204

0.77

 

 

 

 

90/32

 

287

1.09

 

157

0.59

 

135

0.51

gal./day

 

m3/day

100/38

 

223

0.84

 

152

0.57

 

115

0.43

FREEZING CYCLE TIME

70/21

 

 

31

 

 

34

 

 

38

 

 

 

 

80/27

 

 

33

 

 

37

 

 

41

 

 

 

 

90/32

 

 

34

 

 

40

 

 

44

min.

 

 

 

100/38

 

 

35

 

 

41

 

 

48

HARVEST CYCLE TIME

70/21

 

 

4.4

 

 

3.8

 

 

3.5

 

 

 

 

80/27

 

 

4.0

 

 

3.0

 

 

2.9

 

 

 

 

90/32

 

 

3.8

 

 

2.4

 

 

2.2

min.

 

 

 

100/38

 

 

3.1

 

 

2.4

 

 

2.0

HEAD PRESSURE

70/21

 

245

17.2

 

267

18.8

 

296

20.8

 

 

 

 

80/27

 

262

18.4

 

296

20.8

 

324

22.7

PSIG

kg/cm2G

90/32

 

267

18.8

 

320

22.5

 

349

24.5

100/38

 

272

19.1

 

327

23.0

 

375

26.4

 

 

 

 

 

 

 

 

 

 

 

SUCTION PRESSURE

70/21

 

43

3.0

 

44

3.1

 

46

3.2

 

 

 

 

80/27

 

44

3.1

 

46

3.2

 

47

3.3

 

 

 

 

90/32

 

44

3.1

 

47

3.3

 

49

3.4

PSIG

kg/cm2G

100/38

 

44

3.1

 

47

3.3

 

50

3.5

TOTAL HEAT OF REJECTION FROM CONDENSER

 

9639 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.

We reserve the right to make changes in specifications and design without prior notice.

37

Page 37
Image 37
Hoshizaki KM-630MRH, KM-630MWH service manual Performance Data, a KM-630MAH, 1250, 1332