Hoshizaki KM-630MAH IV. SERVICE DIAGNOSIS 1. NO ICE PRODUCTION, Problem, Possible Cause, Remedy

Models: KM-630MAH KM-630MRH KM-630MWH

1 67
Download 67 pages 19.6 Kb
Page 41
Image 41

IV. SERVICE DIAGNOSIS 1. NO ICE PRODUCTION

 

PROBLEM

POSSIBLE CAUSE

 

REMEDY

 

[1] The icemaker

a) Power Supply

1.

“OFF” position.

1.

Move to “ON” position

 

will not start

 

 

2.

Loose connections.

2.

Tighten

 

 

 

 

 

 

3.

Bad contacts.

3.

Check for continuity and

 

 

 

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Voltage too high.

4.

Check and get

 

 

 

 

 

 

 

 

 

recommended voltage.

 

 

b) Fuse (Inside Fused

1.

Blown out.

1. Check for short circuit

 

 

Disconnect, if any)

 

 

 

 

 

 

and replace

 

 

c) Control Switch

1.

“OFF” position.

1.

Move to “ICE” position.

 

 

 

 

2.

Bad contacts.

2.

Check for continuity and

 

 

 

 

 

 

 

 

 

replace.

 

 

d) Bin Control

1.

Tripped with bin filled

1.

Remove ice.

 

 

Thermostat

 

 

 

 

with ice.

 

 

 

 

 

 

 

 

2. Ambient temperature

2. Increase ambient

 

 

 

 

 

 

 

too cool.

 

temperature.

 

 

 

3.

Set too warm.

3.

See “II.2.[d]

 

 

For mechanical

 

 

 

 

 

 

CONTROLS AND

 

 

bin control

 

 

 

 

 

 

ADJUSTMENTS, 5) Bin

 

 

see “II. 3. [c]”

 

 

 

 

 

 

Control.”

 

 

 

 

 

 

4. Bulb out of position.

4.

Place in position.

 

 

 

 

 

 

 

 

 

 

 

 

5.

Bad contacts or leaks

5.

Check for continuity and

 

 

 

 

 

 

 

bulb.

 

replace.

 

 

e) High Pressure

1.

Bad contacts.

1.

Check for continuity and

 

 

Control

 

 

 

 

 

 

replace.

 

 

f) Transformer

1.

Thermal fuse blown out

1. Replace.

 

 

 

 

 

 

 

or coil winding opened.

 

 

 

 

g) Wiring to

1.

Loose connections or

1.

Check for continuity and

 

 

Controller Board

 

 

 

 

open.

 

replace.

 

 

 

 

 

 

 

 

 

h) Thermistor

1.

Leads short-circuit or

1.

See “II.2.[d] CONTROLS

 

 

 

 

 

 

 

open and High

 

AND ADJUSTMENTS, 1)

 

 

 

 

 

 

 

Temperature Safety

 

Defrost Control.”

 

 

 

 

 

 

 

operates.

 

 

 

 

i) Hot Gas Solenoid

1.

Continues to open in

1. Check for power off in

 

 

Valve

 

 

 

 

freeze cycle and High

 

freeze cycle and replace.

 

 

 

 

 

 

 

Temperature Safety

 

 

 

 

 

 

 

 

 

operates.

 

 

 

 

j) Water Supply Line

1.

Water supply off and

1.

Check and get

 

 

 

 

 

 

 

water supply cycle does

 

recommended pressure.

 

 

 

 

 

 

 

not finish.

 

 

 

 

 

 

 

 

2. Condenser water pressure

2.

Check and get

 

 

 

 

 

 

 

too low or off and Pressure

recommended pressure.

 

 

 

 

 

 

 

Control opens and closes

 

 

 

 

 

 

 

 

 

frequently to finally operate

 

 

 

 

 

 

 

 

 

High Temperature Safety.

 

 

 

 

k) Water Solenoid

1.

Mesh filter or orifice gets

1.

Clean.

 

 

 

 

 

 

 

clogged and water supply

 

 

 

 

 

 

 

 

 

cycle does not finish.

 

 

 

 

 

 

2.

Coil winding opened.

2.

Replace.

 

 

 

 

3.

Wiring to Water Valve.

3.

Check for loose connection

 

 

 

 

 

 

 

 

 

or open, and replace.

 

 

 

 

 

 

 

 

 

 

41

Page 41
Image 41
Hoshizaki KM-630MAH, KM-630MWH IV. SERVICE DIAGNOSIS 1. NO ICE PRODUCTION, Problem, Possible Cause, Remedy, For mechanical