Hoshizaki KM-630MRH, KM-630MAH service manual b2 KM-630MWHSerial #M20301E

Models: KM-630MAH KM-630MRH KM-630MWH

1 67
Download 67 pages 19.6 Kb
Page 39
Image 39

[b2] KM-630MWH Serial #M20301E -

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

90/32

 

 

 

 

 

70/21

*621

282

 

603

273

 

563

256

 

 

 

 

80/27

607

275

 

578

262

 

532

241

lbs./day

 

kg./day

 

90/32

603

273

 

*558

253

 

514

233

 

100/38

590

268

 

548

248

 

*473

215

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

*1268

 

 

1271

 

1275

 

CONSUMPTION

80/27

 

1270

 

 

1275

 

1278

 

 

 

 

 

90/32

 

1271

 

 

*1279

 

1282

 

watts

 

 

 

100/38

 

1271

 

 

1280

 

*1285

 

APPROXIMATE WATER

70/21

*653

2.47

 

664

2.51

 

814

3.08

CONSUMPTION PER 24 HR.

80/27

661

2.50

 

720

2.73

 

903

3.42

 

 

 

 

90/32

664

2.51

 

*691

2.62

 

887

3.36

gal./day

 

m3/day

100/38

739

2.80

 

737

2.79

 

*1068

4.04

FREEZING CYCLE TIME

70/21

 

*31

 

 

32

 

35

 

 

 

 

 

80/27

 

32

 

 

34

 

37

 

 

 

 

 

90/32

 

32

 

 

*35

 

38

 

min.

 

 

 

100/38

 

33

 

 

36

 

*41

 

 

 

 

 

 

 

 

 

 

 

HARVEST CYCLE TIME

70/21

 

*3.8

 

 

3.4

 

3.1

 

 

 

 

 

80/27

 

3.5

 

 

2.8

 

2.7

 

 

 

 

 

90/32

 

3.4

 

 

*2.3

 

2.1

 

min.

 

 

 

100/38

 

3.4

 

 

2.3

 

*2.0

 

HEAD PRESSURE

70/21

*280

19.7

 

280

19.7

 

286

20.1

 

 

 

 

80/27

280

19.7

 

280

19.7

 

288

20.2

PSIG

kg/cm2G

90/32

280

19.7

 

*280

19.7

 

288

20.2

100/38

282

19.9

 

285

20.0

 

295

20.7

 

 

 

 

 

 

 

 

 

 

SUCTION PRESSURE

70/21

*47

3.3

 

47

3.3

 

48

3.4

 

 

 

 

80/27

47

3.3

 

48

3.4

 

49

3.4

 

 

 

 

90/32

47

3.3

 

*48

3.4

 

49

3.4

PSIG

kg/cm2G

100/38

48

3.3

 

48

3.4

 

*50

3.5

TOTAL HEAT OF REJECTION FROM CONDENSER

8770 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

1894 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

WATER FLOW FOR CONDENSER

39 gal. / h (AT 100ºF (38ºC) / WT 90ºF (32ºC))

PRESSURE DROP OF COOLING WATER LINE

less than 10 PSIG

Note: Pressure data is recorded at 5 minutes into freeze cycle. The data without * should be used for reference only.

We reserve the right to make changes in specifications and design without prior notice.