KM-630MWH b1 KM-630MRHwith auxiliary codes L-0, M-0, M-1, Note Pressure Switch, Cut-out
Models:
KM-630MAH
KM-630MRH
KM-630MWH
1
33
67
67
Download
67 pages
19.6 Kb
30
31
32
33
34
35
36
37
<
>
Troubleshooting
Specification
Install
Wiring Diagrams
V. Removal And Replacement Of Components
Maintenance
Problem
Cleaning And Sanitizing Procedures
2Defrost Timer
d CONTROLS AND ADJUSTMENTS
Page 33
Image 33
[b1]
KM-630MRH
(with auxiliary codes
L-0,
M-0,
M-1)
Note: Pressure Switch
Cut-out
412
+ 21
PSIG
- 0
Cut-in
327 ± 21
PSIG
33
U1GMA0179608
Page 32
Page 34
Page 33
Image 33
Page 32
Page 34
Contents
KM-630MAH KM-630MWH KM-630MRH
HOSHIZAKI MODULAR CRESCENT CUBER
MODEL
Page
CONTENTS
V. REMOVAL AND REPLACEMENT OF COMPONENTS
IV. SERVICE DIAGNOSIS
1. SERVICE FOR REFRIGERANT LINES
a REFRIGERANT RECOVERY
KM-630MAH
SPECIFICATIONS
2a. KM-630MWHSerial #L00001D - M20270B
2b. KM-630MWHSerial #M20301E
3. KM-630MRH
URC-6F
4. CONDENSER UNIT
MODEL URC-6F
SPECIFICATIONS
II.GENERAL INFORMATION 1. CONSTRUCTION
aKM-630MAH
Mechanical Bin Control
b KM-630MWH
Spray Tubes Control Switch
c KM-630MRH
Expansion Valve Compressor Float Switch
Water Pump Mechanical
2. CONTROLLER BOARD
Features of Control Products “E” Controller Board
a SOLID-STATECONTROL
b CONTROLLER BOARD
3High Temperature Safety - 127 ± 7F
2Defrost Timer
4Low Water Safety
6LED Lights and Audible Alarm Safeties
Harvest Cycle
1 Minute Fill Cycle
Freeze Cycle
Reverse Pump Out
Control Products HOS-001ABoard
cSEQUENCE 1st Cycle
2nd Cycle and after with pump drain
2nd Cycle and after with no pump drain
d CONTROLS AND ADJUSTMENTS
FOR MODELS WITH MECHANICAL BIN CONTROL
FOR MODELS WITH THERMOSTAT
Temperature F
Switch Nos. 9 and
iDisconnect the connector K3 on the board
1 Defrost Control
SETTING
2 Defrost Timer
Dip Switch
Dip Switch
MODELS WITH THERMOSTAT
e CHECKING THE CONTROLLER BOARD
MODELS WITH MECHANICAL BIN CONTROL
aPROXIMITY SWITCH
3. MECHANICAL BIN CONTROL
bEXPLANATION OF OPERATION
cTROUBLESHOOTING MECHANICAL BIN CONTROL ONLY
III. TECHNICAL INFORMATION
1.WATER CIRCUIT AND REFRIGERANT CIRCUIT
aKM-630MAH
b KM-630MWH
c KM-630MRH
2. WIRING DIAGRAMS
Page
Note Pressure Switch
b1 KM-630MRHwith auxiliary codes L-0, M-0, M-1
Cut-out
PSIG
b2 KM-630MRHwith auxiliary codes M-2and after
3. TIMING CHART
Page
a KM-630MAH
4.PERFORMANCE DATA
1250
1332
b1 KM-630MWHSerial #L00001D - M20270B
b2 KM-630MWHSerial #M20301E
APPROXIMATE ICE
c KM-630MRH
1332
1414
PROBLEM
IV. SERVICE DIAGNOSIS 1. NO ICE PRODUCTION
POSSIBLE CAUSE
REMEDY
PROBLEM
POSSIBLE CAUSE
REMEDY
PROBLEM
POSSIBLE CAUSE
REMEDY
2. EVAPORATOR IS FROZEN UP
3. LOW ICE PRODUCTION
4. ABNORMAL ICE
5. OTHERS
1.SERVICE FOR REFRIGERANT LINES
V. REMOVAL AND REPLACEMENT OF COMPONENTS
a REFRIGERANT RECOVERY
bEVACUATION AND RECHARGE R-404A
2. BRAZING DANGER
3.REMOVAL AND REPLACEMENT OF COMPRESSOR IMPORTANT
17Replace the panels in their correct positions
18Turn on the power supply
5.REMOVAL AND REPLACEMENT OF EXPANSION VALVE
4. REMOVAL AND REPLACEMENT OF DRIER
7Install the new Drier
6Install the new valve
1Turn off the power supply 2Remove the panels
7Install the new Drier
14Turn on the power supply
7.REMOVAL AND REPLACEMENT OF EVAPORATOR IMPORTANT
1Turn off the power supply
Page
1Turn off the power supply
11.REMOVAL AND REPLACEMENT OF THERMISTOR CAUTION
12. REMOVAL AND REPLACEMENT OF FAN MOTOR
14. REMOVAL AND REPLACEMENT OF PUMP MOTOR
13. REMOVAL AND REPLACEMENT OF WATER VALVE
15. REMOVAL AND REPLACEMENT OF SPRAY TUBES
1. PREPARING THE ICEMAKER FOR LONG STORAGE
VI. CLEANING AND MAINTENANCE INSTRUCTIONS
Page
2. CLEANING AND SANITIZING PROCEDURES
aCLEANING PROCEDURE
23Move the Control Switch to the “Wash” position
21Turn off the power supply after 3 minutes
26Turn off the power supply after 5 minutes
19Replace the Front Panel in its correct position
b SANITIZING PROCEDURE
3. MAINTENANCE