[c] KM-630MRH
APPROXIMATE ICE | AMBIENT TEMP. |
|
|
|
| WATER TEMP. (ºF/ºC) |
|
|
| |||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
|
| 50/10 |
| 70/21 |
|
|
| 90/32 | ||||||
|
|
|
| 70/21 |
| 603 |
| 274 |
| 573 |
| 260 |
| 531 |
| 241 |
|
|
|
| 80/27 |
| 580 |
| 263 |
| 532 |
| 242 |
| 491 |
| 223 |
|
|
|
| 90/32 |
| 573 |
| 260 |
| 499 |
| 226 |
| 457 |
| 207 |
lbs./day |
| kg./day |
| 100/38 |
| 564 |
| 256 |
| 489 |
| 222 |
| 418 |
| 190 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
APPROXIMATE ELECTRIC | 70/21 |
|
| 1332 |
| 1356 |
|
|
| 1322 | ||||||
CONSUMPTION | 80/27 |
|
| 1350 |
| 1387 |
|
|
| 1316 | ||||||
|
|
|
| 90/32 |
|
| 1356 |
| 1414 |
|
|
| 1358 | |||
watts |
|
|
| 100/38 |
|
| 1326 |
| 1401 |
|
|
| 1306 | |||
APPROXIMATE WATER | 70/21 |
| 323 |
| 1.22 |
| 277 |
| 1.05 |
| 245 |
| 0.93 | |||
CONSUMPTION PER 24 HR. | 80/27 |
| 288 |
| 1.09 |
| 217 |
| 0.82 |
| 201 |
| 0.76 | |||
|
|
|
| 90/32 |
| 277 |
| 1.05 |
| 166 |
| 0.63 |
| 143 |
| 0.54 |
gal./day |
| m3/day | 100/38 |
| 221 |
| 0.84 |
| 161 |
| 0.61 |
| 121 |
| 0.46 | |
FREEZING CYCLE TIME | 70/21 |
|
| 31 |
| 33 |
|
|
| 37 | ||||||
|
|
|
| 80/27 |
|
| 33 |
| 36 |
|
|
| 40 | |||
|
|
|
| 90/32 |
|
| 33 |
| 39 |
|
|
| 43 | |||
min. |
|
|
| 100/38 |
|
| 34 |
| 39 |
|
|
| 47 | |||
HARVEST CYCLE TIME | 70/21 |
|
| 4.1 |
| 3.6 |
|
|
| 3.3 | ||||||
|
|
|
| 80/27 |
|
| 3.7 |
| 2.9 |
|
|
| 2.8 | |||
|
|
|
| 90/32 |
|
| 3.6 |
| 2.4 |
|
|
| 2.2 | |||
min. |
|
|
| 100/38 |
|
| 3.0 |
| 2.4 |
|
|
| 2.0 | |||
HEAD PRESSURE | 70/21 |
| 232 |
| 16.3 |
| 240 |
| 16.9 |
| 263 |
| 18.5 | |||
|
|
|
| 80/27 |
| 238 |
| 16.8 |
| 251 |
| 17.6 |
| 281 |
| 19.8 |
PSIG | kg/cm2G | 90/32 |
| 240 |
| 16.9 |
| 260 |
| 18.3 |
| 288 |
| 20.2 | ||
100/38 |
| 249 |
| 17.5 |
| 266 |
| 18.7 |
| 313 |
| 22.0 | ||||
SUCTION PRESSURE | 70/21 |
| 42 |
| 3.0 |
| 42 |
| 3.0 |
| 45 |
| 3.2 | |||
|
|
|
| 80/27 |
| 42 |
| 3.0 |
| 43 |
| 3.0 |
| 47 |
| 3.3 |
|
|
|
| 90/32 |
| 42 |
| 3.0 |
| 43 |
| 3.0 |
| 47 |
| 3.3 |
PSIG | kg/cm2G | 100/38 |
| 44 |
| 3.1 |
| 44 |
| 3.1 |
| 50 |
| 3.5 | ||
|
|
|
|
|
|
|
|
|
| |||||||
TOTAL HEAT OF REJECTION FROM CONDENSER |
|
| 8512 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] | |||||||||||||
TOTAL HEAT OF REJECTION FROM COMPRESSOR |
| 1775 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] | ||||||||||||||
CONDENSER VOLUME |
|
|
|
| 40 CU. IN |
|
|
|
|
|
|
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.
We reserve the right to make changes in specifications and design without prior notice.
40