Hoshizaki KM-630MAH, KM-630MWH, KM-630MRH service manual

Models: KM-630MAH KM-630MRH KM-630MWH

1 67
Download 67 pages 19.6 Kb
Page 62
Image 62
Fig. 4

9)Attach compressed air or carbon dioxide supply to the Condenser Water Line Drain Valve.

10)Quickly blow the water-cooled Condenser out, using compressed air or carbon

[2]Remove the water from the potable water supply line:

1)Remove the Front Panel. (Except water-cooled model)

2)Move the Control Switch, on the Control Box, to the “OFF” position.

3)Wait 3 minutes.

4)Close the Potable Water Supply Line Shut-off Valve and open the Potable Water Supply Line Drain Valve.

5)Allow the line to drain by gravity.

6)Attach compressed air or carbon dioxide supply to the Potable Water Line Drain Valve.

7)Move the Control Switch to the “ICE” position.

8)Blow the potable water line out using compressed air or carbon dioxide.

[3]Drain the Potable Water Tank:

1)Turn off the power supply.

2)Move the Control Switch to the “OFF” position.

3)Drain the Water Tank by removing the base cover and one end of the pump tubing. See Fig. 4.

4)Replace the removed parts in their correct

positions.

Fig. 4

5)Remove all ice from the Storage Bin, and clean the Storage Bin.

6)Replace the Front Panel in its correct position.

7)Close the Drain Valve.

62