"G" Control Board Sequence Flow Chart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KMS-1401MLJ with SRK-14J/3

 

 

 

 

 

 

2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sequence

Cycle

 

 

 

1. 1-Minute

 

 

2. Harvest Cycle

 

 

 

 

 

 

 

 

 

 

 

 

3. Freeze Cycle

 

 

 

4. Pump-Out Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steps

 

Fill Cycle

 

 

• WV2 time: 6 min. or the length of harvest minus 50 sec.

 

 

 

• Minimum freeze time: 5 min.

 

Factory set for every

 

 

 

 

 

 

 

 

 

 

 

 

 

(S4 dip switch 7), whichever is shorter.

 

 

 

• Maximum freeze time: freeze timer setting

 

10th cycle.

 

 

 

 

 

 

 

 

 

 

 

 

• Maximum harvest time: 20 min.

 

 

 

 

(S4 dip switch 9 & 10).

 

 

 

 

(S4 dip switch 5 & 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor

 

 

 

1 to 3-min. harvest timer in control

 

 

 

 

5-min. minimum

 

 

F/S in control

 

 

 

 

 

 

Flow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in control

 

 

 

 

 

(S4 dip switch 1 & 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

freeze timer in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Harvest Pump

 

 

 

 

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

Refill

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Startup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 sec.

 

 

1 min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F/S check

 

 

 

F/S closed

 

 

 

 

 

 

 

 

 

 

F/S check

 

 

 

 

F/S closed

 

 

 

 

 

 

F/S opens or freeze

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WV1 energized

 

 

Comp energized

 

 

 

PM energized

 

 

 

Comp continues

timer terminates

Comp continues

 

 

 

 

 

 

 

 

 

 

 

 

WV2 de-energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FMRs energized

 

 

 

 

 

 

FMRs continue

 

 

 

FMRs continue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F/S open

 

 

HGVs energized

 

Thermistor temperature reaches

 

 

 

PM continues

 

 

 

HGVs energized

 

 

 

 

 

 

 

 

 

 

 

 

WV2 energized

 

 

 

 

LLVs energized

 

 

 

DV & PM de-energized 2 sec., then

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48°F (9°C) (3.9 kor less).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WV1 de-energized

 

 

 

 

WV1 energized first 1 min. of freeze

 

energized for 10/20 sec.

 

 

 

 

 

 

 

 

 

 

 

 

Harvest timer starts (1 to 3 min.).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HGVs de-energized

 

 

 

LLVs de-energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F/S open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If F/S is open, Comp stops and cycle returns to 1-min. fill.

Shutdown

 

1. Bin Full

 

and Restart

Shutdown Delay:

Fill Cycle – 15 sec. after activation.

Harvest Cycle – At the end of the harvest cycle, or up to 15 sec. into the freeze cycle if activated at the end of the harvest cycle.

Freeze Cycle – 15 sec. after activation if activated at least 15 sec. before the 5-min. short cycle protection timer terminates. Otherwise, at the end of the next harvest cycle.

BC Operation

2.Icemaker Off

All components de-energized.

3.Ice Level Lowered

Icemaker starts at "1. 1-Minute Fill Cycle."

To 1 above

BC open (BC actuator paddle engaged)

Green "BC CLOSED" LED off

Yellow "BC OPEN" LED on

Legend:

Comp-compressor

DV-drain valve

FMRs-fan motors-remote

F/S-float switch

HGVs-hot gas valves (KMS and SRK)

LLVs-liquid line valves (KMS and SRK)

PM-pump motor

WV1-fill/refill water valve

WV2-harvest water valve

Yellow "BC OPEN" LED continues BC closed (BC actuator paddle disengaged)

All components deenergized Green "BC CLOSED" LED on

Yellow "BC OPEN" LED off

Components Energized when the Control Switch is in the "SERVICE" Position

When in the "SERVICE" position, the control switch supplies power to the service switch and the icemaker is in service mode. The service switch has three positions: "DRAIN," "CIRC." and "WASH." See the information below for details of each function.

DRAIN

Power is supplied to the pump and drain valve. This drains the water tank.

 

 

CIRC.

Power is supplied to the pump only. This operation can be used to circulate cleaner and

 

sanitizer over the outside surface of the evaporator for extended periods of time.

 

 

WASH

Power is supplied to the pump and wash valve. This operation is used to circulate cleaner

 

and sanitizer over both the inside and outside surfaces of the evaporator.

 

 

Page 15
Image 15
Hoshizaki Condensing Unit Models SRK-14J/3, KMS-1401MLJ service manual Flow, Sequence

Condensing Unit Models SRK-14J/3, KMS-1401MLJ specifications

The Hoshizaki KMS-1401MLJ and the Condensing Unit Models SRK-14J/3 are critical components in the commercial refrigeration sector, designed to provide efficient and reliable cooling for various applications. These models stand out for their exceptional performance, advanced technologies, and robust characteristics that meet the demanding needs of food service, hospitality, and retail establishments.

One of the primary features of the Hoshizaki KMS-1401MLJ is its high-capacity cooling capability. With a refrigerating capacity suitable for larger applications, this unit is designed to handle significant load demands while maintaining energy efficiency. This is particularly advantageous in environments where consistent temperature control is vital for preserving perishable goods.

The SRK-14J/3 models further enhance the functionality of this system by incorporating advanced inverter technology. This innovation allows for variable speed operation, adjusting the compressor's output based on the actual cooling demand. As a result, users can experience reduced energy costs and lower environmental impact. This efficiency not only decreases the overall operating expenses but also extends the lifespan of the unit due to reduced wear and tear on the compressor.

The Hoshizaki units are also renowned for their user-friendly interface, which features intuitive controls for easy operation and monitoring. This ensures that users can quickly adjust settings to accommodate specific storage needs, improving overall convenience and efficiency in the workplace.

Additionally, both the KMS-1401MLJ and the SRK-14J/3 models are designed with durability in mind. Constructed from high-quality materials, they are built to withstand the rigorous demands of a commercial kitchen or storage facility. Features such as corrosion-resistant coatings and robust insulation enhance the longevity of these units, making them a wise investment for business owners.

In terms of maintenance, Hoshizaki has incorporated several design elements to facilitate ease of service. Access points for routine checks and cleaning have been strategically placed, enabling technicians to perform maintenance tasks without disrupting the operation of the units.

In conclusion, the Hoshizaki KMS-1401MLJ and Condensing Unit Models SRK-14J/3 offer a perfect blend of efficiency, durability, and technological advancement. Their ability to provide reliable cooling solutions makes them integral to any establishment focused on quality and performance in food and beverage storage. For businesses seeking to enhance operational efficiency while ensuring the preservation of their products, these models represent a leading choice in the commercial refrigeration market.