1. Control Board Layout
"G" Control Board
• "ALARM RESET" Button • S4 Dip Switch
•Bin Control Switch Closed LED (green)
•Bin Control Switch Open LED (yellow)
•Part Number
• Alarm Buzzer
•Power LED (red)
(lights when 10.5VAC is supplied
to K2 connector)
•Relay LEDs
(4) (indicate which
relays are energized and which K1 connector pins are energized
•LED 2 (X2 Relay)
LED 2 on:
K1 Connector Pin #2 LED 2 off:
K1 Connector Pin #3
• "OUTPUT TEST" Button
(used to test relays on control board)
• K3 (white) Connector Harvest Control (thermistor)
• K4 (red) Connector
Bin Control
• S5 Dip Switch
• K5 (black) Connector
Float Switch
• Label
(control board revision level indicated on label on side of relay)
• K1 Connector Pins #1 through #10
#1, 9 Magnetic Contactor, X13 Relay (holding circuit during Harvest Pump Timer), and
•LED 3 (X3 Relay)
LED 3 on:
K1 Connector Pin #5 (energized during harvest pump timer)
LED 3 off:
K1 Connector Pin #4 (energized in freeze)
•LED 4 (X4 Relay)
K1 Connector Pin #6
•LED 1 (X1 Relay)
K1 Connector Pin #1, #9
•K2 Connector
Control Transformer (10.5VAC)
Drain Valve (during
#2 Hot Gas Valves (KMS and
SRK) and X10 Relay #3 Liquid Line Valves #4 Pump Motor (freeze) #5 X11 Relay (Pump Motor
in Harvest Pump Timer and Drain Valve in
#6 Fill Water Valve (InitialFill and Freeze Fill only); Harvest Water Valve and X12 Relay (Harvest only)
#7, 10 Supply Voltage #8 Open
"G" Control Board
Part Number 2A3792-01
17