Hoshizaki Condensing Unit Models SRK-14J/3 C. Performance Data, KMS-1401MLJ with SRK-14J

Models: Condensing Unit Models SRK-14J/3 KMS-1401MLJ

1 54
Download 54 pages 29.87 Kb
Page 28
Image 28

C. Performance Data

1. KMS-1401MLJ with SRK-14J

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

70/21

 

 

90/32

 

 

 

 

70/21

 

1420

644

1379

626

1278

580

 

 

 

 

80/27

 

1389

630

1325

601

1199

544

lbs./day

 

kg./day

90/32

 

1379

626

1280

581

1162

527

 

100/38

 

1344

609

1252

568

1054

478

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

2410

 

2439

 

 

2492

CONSUMPTION

80/27

 

2432

 

2478

 

 

2537

 

 

 

 

90/32

 

2439

 

2510

 

 

2567

watts

 

 

 

100/38

 

2454

 

2523

 

 

2620

APPROXIMATE WATER

70/21

 

682

2.58

555

2.10

492

1.86

CONSUMPTION PER 24 HR.

80/27

 

585

2.22

388

1.47

386

1.46

 

 

m3/day

90/32

 

555

2.10

250

0.94

220

0.83

gal./day

 

100/38

 

411

1.56

243

0.92

193

0.73

FREEZING CYCLE TIME

70/21

 

24

 

25

 

 

27

 

 

 

 

80/27

 

25

 

26

 

 

29

 

 

 

 

90/32

 

25

 

27

 

 

30

min.

 

 

 

100/38

 

26

 

28

 

 

33

HARVEST CYCLE TIME

70/21

 

4.6

 

3.9

 

 

3.6

 

 

 

 

80/27

 

4.0

 

3.0

 

 

3.1

 

 

 

 

90/32

 

3.9

 

2.2

 

 

2.2

min.

 

 

 

100/38

 

3.1

 

2.2

 

 

2.1

HEAD PRESSURE

70/21

 

178

12.5

197

13.8

219

15.4

 

 

 

 

80/27

 

192

13.5

221

15.6

241

17.0

 

 

 

 

90/32

 

197

13.8

242

17.0

263

18.5

PSIG

kg/cm2G

100/38

 

200

14.1

247

17.4

283

19.9

SUCTION PRESSURE

70/21

 

46

3.2

47

3.3

50

3.5

 

 

 

 

80/27

 

47

3.3

49

3.5

52

3.7

 

 

 

 

90/32

 

47

3.3

51

3.6

54

3.8

PSIG

kg/cm2G

100/38

 

48

3.4

52

3.6

56

3.9

TOTAL HEAT OF REJECTION FROM CONDENSER

 

28,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

 

 

 

226 CU. IN (SRK-14J)

 

 

 

Note:

1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

28

Page 28
Image 28
Hoshizaki Condensing Unit Models SRK-14J/3 service manual C. Performance Data, KMS-1401MLJ with SRK-14J