F. Diagnostic Charts
1. No Ice Production
No Ice Production - Possible Cause
1. Power Supply | a) Off, blown fuse, or tripped breaker. | |
|
| |
| b) Not within specifications. | |
|
| |
2. Main Transformer | a) Voltage tap switch not set to proper voltage. | |
b) Coil winding open or shorted. | ||
Only) |
| |
3. Water Supply | a) Water supply off or improper water pressure. | |
|
| |
| b) External water filters clogged. | |
|
| |
4. Fuse (SRK Control Box) | a) Blown. | |
|
| |
5. | a) Dirty condenser. | |
| b) Condensing unit fan(s) not operating. | |
| c) Headmaster (C.P.R.) open. | |
|
| |
| d) Refrigerant overcharged. | |
|
| |
| e) Bad contacts. | |
|
| |
| f) Refrigerant lines or components plugged. | |
6. Discharge Line Thermostat | a) Ambient temperature too warm. | |
(SRK) |
| |
b) Compressor or compressor components faulty. | ||
| ||
|
| |
| c) Defective. | |
|
| |
| d) Hot gas valves open. | |
| e) Dirty condenser. | |
|
| |
| f) Condensing unit fan not operating. | |
|
| |
7. Wire Harness | a) Disconnected or loose connection. | |
(From SRK to KMS) |
| |
|
| |
8. Fuse (KMS Switch Box) | a) Blown. | |
9. Control Switch | a) In "SERVICE" or "OFF" position. | |
|
| |
| b) Bad contacts. | |
|
| |
10. Control Transformer | a) Coil winding open or shorted. | |
(115VAC/10.5VAC) |
| |
|
| |
11. Control Board | a) In alarm. | |
See "IV.B. Control Board Check" | b) Yellow "BC OPEN" LED on (bin full). | |
|
| |
| c) Defective. | |
|
| |
12. Bin Control | a) Tripped with bin filled with ice. | |
See "IV.C. Bin Control Check and |
| |
b) Actuator does not move freely. | ||
Cleaning" |
| |
c) Defective. | ||
| ||
|
| |
13. Fill/Refill or Harvest Water Valve | a) Screen or orifice clogged. | |
|
| |
| b) Coil winding open. | |
|
| |
| c) Water valve open in freeze cycle. | |
14. Float Switch | a) Float does not move freely. | |
See "IV.D. Float Switch Check | b) Defective. | |
and Cleaning" | ||
|
40