B. Condensing Unit
1. SRK-14J
AC SUPPLY VOLTAGE |
| ||||
| (115VAC Supplied to KMS via Factory Wire Harness) |
| |||
AMPERAGE | 13.5 A ( 5 Min. Freeze AT 104°F / WT 80°F ) |
| |||
MINIMUM CIRCUIT AMPACITY | 20 A |
|
|
|
|
MAXIMUM FUSE SIZE | 20 A |
|
|
|
|
|
|
| |||
EXTERIOR DIMENSIONS (WxDxH) | 50" x 17" x 28" ( 1270 x 432 x 711 mm ) |
| |||
DIMENSIONS INCLUDING LEGS (WxDxH) |
| ||||
EXTERIOR FINISH | Galvanized steel |
|
|
| |
|
|
|
| ||
WEIGHT | Net 230 lb. (104 kg) | Shipping 275 lb. (125 kg) |
| ||
|
|
| |||
CONNECTIONS - ELECTRIC | Main Power Supply: Permanent Connection |
| |||
| SRK to KMS: Wire Harness Connection |
| |||
- REFRIGERANT | Liquid Line | 1 1/16" - 12 UNF Fitting (#10 Parker) |
| ||
| Suction Line | 1 1/8" - 12 UNF Fitting (#11 Parker) |
| ||
COMPRESSOR | Hermetic, Model |
|
| ||
CONDENSER | Air Cooled, Fin and Tube Type |
|
| ||
COMPRESSOR PROTECTION |
| ||||
FAN MOTOR PROTECTION | Thermal Protection |
|
|
| |
REFRIGERANT CIRCUIT PROTECTION |
|
| |||
|
| ||||
REFRIGERANT CONTROL | Headmaster (C.P.R.) (160 PSI) |
|
| ||
REFRIGERANT CHARGE | 16 lb. 5 oz. (7400g)) |
|
|
| |
| (Condensing Unit 15 lb. 14 oz. (7200g)) |
| |||
| (Icemaker 0 lb. 7.1 oz. (200g)) |
|
| ||
DESIGN PRESSURE | High 467 PSIG, Low 230 PSIG |
|
| ||
|
|
|
| ||
OPERATING CONDITIONS | VOLTAGE RANGE |
| 187 - 253VAC | ||
| AMBIENT TEMP. (Outdoor use) |
| |||
|
|
|
|
|
|
ACCESSORIES | Leg |
|
|
| 2 pcs |
| Hex Head Bolt w/Washer |
| M8x16 | 8 pcs | |
| Hex Nut |
|
| M8 | 8 pcs |
Compatible KMS Icemaker |
|
|
| ||
|
|
| |||
Note: We reserve the right to make changes in specifications and | design without | prior | |||
notice. |
|
|
|
|
|
9