issues Known

Solution:

At this time, this issue is not scheduled to be fixed.

Issue (Internal):

In the Calibration Information section on the Print Diagnostics page from the Diagnostics menu, the value for the Last CPR date does not display.

Solution:

At this time, this issue is not scheduled to be fixed.

Issue (Internal):

When a complex print job that invokes CTB mode is canceled, half of an image still prints.

Description:

The following steps were used to produce this issue:

1.Send a complex print job that invokes CTB mode. After 13 or more seconds, send the ctrl_c command to stop the print job.

2.After 13 seconds, cancel the print job in the control panel.

The printer starts printing when the job is cancelled. It prints an incomplete job.

Solution:

At this time, this issue is not scheduled to be fixed.

Issue (Internal):

When the PATT InitFileSystem ALL command is initialized, the print jobs that should have been deleted still remain.

Description:

The following steps were used to produce this issue:

1.Using the latest firmware, set any view in the configuration specifications.

2.cd /fw/test/INTERACTIVES/job/jobmanager/Print500jobs/Print500jobs.patt

3.Execute the script with the following command: patt -f Print500jobs.patt -n (IP) - pn apache

4.After it stores all the jobs, initialize the disk through the following PATT command:

InitFileSystem ALL

Only some of the print jobs are deleted.

Solution:

At this time, this issue is not scheduled to be fixed.

4 Chapter A Known issues