Solution:

At this time, this issue is not scheduled to be fixed.

Issue (Internal):

With firmware version 03.015.3, the vc_ring_dump triage script is outputting events as numbers, instead of as symbolic names.

Solution:

At this time, this issue is not scheduled to be fixed.

Issue (Internal):

When running a duration-profile test suite with firmware versions 03.017.0, a 49.4C02 ERROR or 49.4602 ERROR displays on the control panel.

Description:

To produce this issue, run the following print jobs in a loop:

/fw/test/S_SUBSYSTEMS/duration/PrintPCL5/perform_pcl_acts.pcl.0600

/projects/copern/test/current/pcl/fontr_tt/ppmtrics/ppmtrics.obj

Solution:

At this time, this issue is not scheduled to be fixed.

Issue (Internal):

When running a duration-profile test suite with firmware versions 03.017.0, a 49.1D16 ERROR displays on the control panel.

Description:

To produce this issue, run the following print job:

/fw/platforms/sfp/products/apache/subsystems/odController/src/ODCClassImpl.cxx

Solution:

At this time, this issue is not scheduled to be fixed.

Issue (Internal):

With firmware version 03.017.0 for held (stored) print jobs, TileSmart Table of contents (TOC) allocations use the wrong memory pool.

Description:

With no hard disk, held print jobs are stored in RAM as compressed strips. Because of the TileSmart feature, each strip has separate memory allocations. The TOC strip allocations are in both the Compressed Strips pool and the Personality Pool. The TOC strips should not be allowed to fill up the Compressed Strips pool.

Known issues

ENWW

General firmware [INTERNAL] 9