Operation

Examples

 

 

Display stacking link configuration and status

>show stackinglink

 

 

Display the system log

>show systemlog

 

 

 

Display a list of servers in the domain

Summary display

 

 

>show server

 

Detailed display

 

 

>show server *

 

Single server display

 

 

>show server enc0:1

 

 

>show server 2

 

 

 

Display server profiles

Summary display

 

 

>show profile

 

Detailed display

 

 

>show profile *

 

Single profile display

 

 

>show profile MyProfile

 

 

Delete the domain configuration

>delete domain

 

 

Update interconnect module firmware

>update firmware

 

url=http://www.mywebserver.com/images/vc-

 

1.20.rom

 

 

Force a failover to the standby VC Manager

>reset vcm - failover

 

 

Power off server blades

>poweroff server enc0:2

 

>poweroff server 3

 

>poweroff server *

 

 

Power on server blades

>poweron server enc0:1

 

>poweron server 2

 

>poweron server *

 

 

Reset a server blade

>reboot server enc0:4

 

>reboot server 6

 

>reboot server *

 

 

Unassign a server profile from a device bay

>unassign profile MyProfile

 

 

Modify Ethernet network connection properties

>set enet-connection MyProfile 1

 

pxe=disabled

 

 

Modify FC fabric connections

>set fc-connection MyProfile 2 speed=auto

 

 

 

Resetting the Virtual Connect Manager

To reset the Virtual Connect Manager, use the reset vcm command:

>reset vcm

>reset vcm [-failover]

Administrator privileges are required for this operation.

If VC Ethernet Modules are installed in I/O bays 1 and 2 of the enclosure, the user can manually change which Virtual Connect Ethernet Module is hosting the Virtual Connect Manager through the use of this feature. The feature can also force the Virtual Connect manager to restart without switching to the

Configuring the Virtual Connect domain using the CLI 51