Operation | Examples | |
|
| |
Display stacking link configuration and status | >show stackinglink | |
|
| |
Display the system log | >show systemlog | |
|
|
|
Display a list of servers in the domain | • | Summary display |
|
| >show server |
| • | Detailed display |
|
| >show server * |
| • | Single server display |
|
| >show server enc0:1 |
|
| >show server 2 |
|
|
|
Display server profiles | • | Summary display |
|
| >show profile |
| • | Detailed display |
|
| >show profile * |
| • | Single profile display |
|
| >show profile MyProfile |
|
| |
Delete the domain configuration | >delete domain | |
|
| |
Update interconnect module firmware | >update firmware | |
| url=http://www.mywebserver.com/images/vc- | |
| 1.20.rom | |
|
| |
Force a failover to the standby VC Manager | >reset vcm - failover | |
|
| |
Power off server blades | >poweroff server enc0:2 | |
| >poweroff server 3 | |
| >poweroff server * | |
|
| |
Power on server blades | >poweron server enc0:1 | |
| >poweron server 2 | |
| >poweron server * | |
|
| |
Reset a server blade | >reboot server enc0:4 | |
| >reboot server 6 | |
| >reboot server * | |
|
| |
Unassign a server profile from a device bay | >unassign profile MyProfile | |
|
| |
Modify Ethernet network connection properties | >set | |
| pxe=disabled | |
|
| |
Modify FC fabric connections | >set | |
|
|
|
Resetting the Virtual Connect Manager
To reset the Virtual Connect Manager, use the reset vcm command:
>reset vcm
>reset vcm [-failover]
Administrator privileges are required for this operation.
If VC Ethernet Modules are installed in I/O bays 1 and 2 of the enclosure, the user can manually change which Virtual Connect Ethernet Module is hosting the Virtual Connect Manager through the use of this feature. The feature can also force the Virtual Connect manager to restart without switching to the