Compatibility Language - B

 

STATUS

 

 

 

 

 

 

REGISTER

 

 

 

 

 

CV

1

 

 

 

 

 

 

 

 

 

 

 

+CC

2

 

 

 

 

 

 

 

 

 

 

 

UNR

4

 

 

 

 

 

OV

8

 

 

 

 

 

OT

16

 

 

 

 

 

 

 

 

 

 

 

not used

32

 

 

 

 

 

OC

64

 

 

FAULT

 

 

 

 

 

 

 

 

ERR

128

 

 

REGISTER

 

 

 

 

 

 

 

 

INH

256

 

 

 

 

 

 

 

 

1

 

 

 

512

 

 

 

 

-CC

 

 

 

 

 

 

 

 

2

 

 

FAST

1024

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

NORM

2048

 

 

 

SERIAL

 

 

 

 

 

 

 

8

 

 

 

 

 

 

POLL

 

 

 

 

16

 

 

ACCUMULATED

 

 

 

REGISTER

 

 

 

32

FAU

 

STATUS

 

MASKUS

1

 

 

REGISTER

64

 

 

REGISTER

 

 

 

 

 

 

PON

2

 

 

 

128

 

 

 

 

 

 

 

 

 

 

 

1

CV

1

256

not used

4

 

 

 

2

+CC

2

512

not used

8

 

4

UNR

4

1024

RDY

16

 

 

 

8

OV

8

2048

ERR

32

 

 

 

 

 

64

 

16

OT

16

 

RQS

 

 

 

 

32

not used

32

 

not used

128

 

 

 

 

64

OC

64

 

 

 

 

128

ERR

128

 

 

 

 

256

INH

256

 

 

 

 

 

 

 

 

 

512

-CC

512

 

 

 

 

 

 

 

 

 

1024

FAST

1024

 

 

 

 

 

 

 

 

 

2048

NORM

2048

 

 

 

 

 

 

 

 

 

 

 

Figure B-1. COMpatibility Status Model

 

 

 

 

 

Table B-4. Bit Assignment of Status, Astatus, Fault, & Mask Registers

 

 

Bit Position

11

10

 

9

8

7

6

5

4

3

2

1

0

Bit Name

NORM

FAST

 

-CC

INH

ERR

OC

not

OT

OV

UNR

+CC

CV

 

 

 

 

 

 

 

 

used

 

 

 

 

 

Bit Weight

2048

1024

 

512

256

128

64

32

16

8

4

2

1

CV = The unit is operating in constant voltage mode.

CC+ = The unit is operating in constant current mode.

UNR = The output of the unit is unregulated.

OV = The overvoltage protection circuit has tripped.

OT = The over-temperature protection circuit has tripped.

OC = The overcurrent protection circuit has tripped.

ERR = A programming error has occurred. Use ERR? to clear.

CC= The unit is operating in negative constant current mode.

INH = The external remote inhibit signal has turned the output off.

FAST = The output is in Fast operating mode. (Agilent 66332A, 6631B, 6632B, 6633B, 6634B only) NORM = The output is in Normal operating mode. (Agilent 66332A, 6631B, 6632B, 6633B, 6634B only)

 

 

Table B-5. Bit Configuration of Serial Poll Register

 

 

Bit Position

7

6

5

4

3

2

1

0

Bit Name

not used

RQS

ERR

RDY

not used

not used

PON

FAU

Bit Weight

 

64

32

16

 

 

2

1

RQS = The dc source has generated a service request. Use a serial poll to clear. ERR = Same as ERR bit in Status register. Use ERR? to clear.

RDY = This bit cleared when unit busy processing commands. Set when processing complete. PON = A Power-on has occurred. Use CLR to clear.

FAU = A bit has been set in the Fault register. Use FAULT? to clear.