Language Dictionary - 4

TRIGger:SEQuence2:COUNt:CURRent

TRIGger:ACQuire:COUNt:CURRent

Agilent 66312A, 66332A Only

This command sets up a successive number of triggers for measuring current data. With this command, the trigger system needs to be initialized only once at the start of the acquisition period. After each completed measurement, the instrument waits for the next valid trigger condition to start another measurement. This continues until the count has completed.

Command Syntax

TRIGger:SEQuence2:COUNt:CURRent<NRf+>

 

TRIGger:ACQuire:COUNt:CURRent<NRf+>

Parameters

1 to 100

 

*RST Value

1

 

Examples

TRIG:SEQ2:COUN:CURR 5 TRIG:ACQ:COUN:CURR 1

Query Syntax

TRIGger:SEQuence2:COUNt:CURRent?

 

TRIGger:ACQuire:COUNt:CURRent?

Returned Parameters

<NR3>

 

Related Commands

TRIG:SEQ2

TRIG:ACQ

TRIGger:SEQuence2:COUNt:VOLTage

TRIGger:ACQuire:COUNt:VOLTage

Agilent 66312A, 66332A Only

This command sets up a successive number of triggers for measuring voltage data. With this command, the trigger system needs to be initialized only once at the start of the acquisition period. After each completed measurement, the instrument waits for the next valid trigger condition to start another measurement. This continues until the count has completed.

Command Syntax

TRIGger:SEQuence2:COUNt:VOLTage<NRf+>

 

TRIGger:ACQuire:COUNt:VOLTage<NRf+>

Parameters

1 to 100

 

 

*RST Value

1

 

 

Examples

TRIG:SEQ2:COUN:VOLT 5

TRIG:ACQ:COUN:VOLT 1

Query Syntax

TRIGger:SEQuence2:COUNt:VOLTage?

 

TRIGger:ACQuire:COUNt:VOLTage?

Returned Parameters

<NR3>

 

 

Related Commands

TRIG:SEQ2

TRIG:ACQ

 

75