4 - Language Dictionary

OUTPut:PON:STATe

This command selects the power-on state of the dc source. This information is saved in non-volatile memory. The following states can be selected:

RST

RCL0

Sets the power-on state to *RST. Refer to the *RST command as described in this chapter for more information.

Sets the power-on state to *RCL 0. Refer to the *RCL command as described in this chapter for more information.

Command Syntax

OUTPut:PON:STATe <state>

Parameters

RST RCL0

Examples

OUTP:PON:STAT RST

Query Syntax

OUTPut:PON:STATe?

Returned Parameters

<CRD>

Related Commands

*RST *RCL

OUTPut:PROTection:CLEar

This command clears the latch that disables the output when an OverVoltage, OverCurrent, OverTemperature, Remote Inhibit, or Fuse Status condition is detected. All conditions that generate the fault must be removed before the latch can be cleared. The output is then restored to the state it was in before the fault condition occurred.

Command Syntax

OUTPut:PROTection:CLEar

Parameters

None

Examples

OUTP:PROT:CLE

Related Commands

OUTP:PROT:DEL *RCL *SAV

OUTPut:PROTection:DELay

This command sets the time between the programming of an output change that produces a constant current condition (CC) and the recording of that condition by the Operation Status Condition register. The delay prevents the momentary changes in status that can occur during reprogramming from being registered as events by the status subsystem. Since the constant current condition is used to trigger overcurrent protection (OCP), this command also delays OCP. Overvoltage protection is not affected by this comand.

Command Syntax

OUTPut:PROTection:DELay <NRf+>

Parameters

0 to 2,147,483.647

Unit

seconds

*RST Value

0.08 (Normal)

Examples

OUTPUT:PROTECTION:DELAY 75E-1

Query Syntax

OUTPut:PROTection:DELay?

Returned Parameters

<NR3>

Related Commands

OUTP:PROT:CLE *RCL *SAV