HP 8517B manual Sample Diagnostics, Test Results for Path 1 through Path

Models: 8517B

1 136
Download 136 pages 17.64 Kb
Page 83
Image 83

Troubleshooting the Test Set

Troubleshooting Procedures

Finding the Faulty Compare the results recorded in Table 5-6with the matrix in Table 5-7.Assembly There are 32 possible combinations, twelve of which point to probable

failures. These are shown in Table 5-7.

Table 5-6 Test Results for Path 1 through Path 6

a1

a2

b1

b2

b1 thru

b2 thru

Path1

Path2

Path 3

Path 4

Path5

Path6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sample Diagnostics

Suppose you have determined that paths 3 and 5 are bad. Paths 1, 2, 4, and 6 are good. Refer to Table 5-7.Notice that the most likely cause for the failure is the b1 sampler.

Table 5-7 Most Probable Failures (B indicates Bad; indicates Good)

 

 

 

Path

 

 

 

Most Probable Failure

 

 

 

 

 

 

 

a1

a2

b1

b2

b1 thru

b2 thru

Assembly, or Description of Condition

Path1

Path2

Path 3

Path 4

Path5

Path6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The HP

8517B test set is not the problem

 

 

 

 

 

 

 

B

B

B

B

B

B

The source, source cable, VTO, cables from rear

 

 

 

 

 

 

panel to switch splitter

 

 

 

 

 

 

 

B

B

B

The switch splitter

 

 

 

 

 

 

 

B

B

B

The switch splitter

 

 

 

 

 

 

 

B

B

b1 sampler

 

 

 

 

 

 

 

B

a1 sampler

 

 

 

 

 

 

 

B

a2 sampler

 

 

 

 

 

 

 

B

B

b2 sampler

 

 

 

 

 

 

 

B

B

B

Port 1 connector or directional coupler

 

 

 

 

 

 

 

 

B

B

B

A1, T1

 

 

 

 

 

 

 

 

 

B

B

A2, T2

 

 

 

 

 

 

 

 

B

B

B

Port 2 connector or directional coupler

 

 

 

 

 

 

 

 

HP 8517B S-Parameter Test Set Manual 5-23

Page 83
Image 83
HP 8517B Sample Diagnostics, Test Results for Path 1 through Path, Most Probable Failures B indicates Bad indicates Good