HP 8517B Test Set Replacement Procedures

Assembly Replacement Procedures

Input Amplifier

A22 Input Amplifier Assembly

Replacement

 

 

 

 

NOTE

This procedure is for Option 007, Option 002 “plus” 007, and Option 004

 

“plus” 007, only.

 

1.

See the figure in Chapter 7, Table 7-17for the location of the A22

 

 

 

amplifier.

 

2.

Without disconnecting AT1 and AT2 fixed attenuators, remove the other

 

 

five semi-rigid cables attached to the A18 switch/splitter.

 

3.

Remove the W45 semi-rigid cable between the A22 input amplifier and

 

 

J7 rear-panel RF input connector.

 

4.

Remove the two screws holding the switch/splitter to the amplifier

 

 

mount bracket.

 

5.

Remove the switch/splitter from the amplifier mount bracket.

 

6.

Remove the four screws that secure the A22 input amplifier to the

 

 

amplifier-mount bracket.

Buffer Amplifier

A23 to A26 Buffer Amplifiers

Replacement

 

 

 

 

NOTE

This procedure is for Option 007, Option 002 “plus” 007, and Option 004

 

“plus” 007, only.

 

1.

See the figure in Chapter 7, Table 7-17for the location of the buffer

 

 

 

amplifiers.

 

2.

Remove the two semi-rigid cables from the buffer amplifier to be

 

 

replaced.

 

3.

Remove the four screws securing the buffer amplifier to the amplifier

 

 

mount bracket.

 

4.

Remove the buffer amplifier.

6-12HP 8517B S-Parameter Test Set Manual

Page 96
Image 96
HP 8517B manual A22 Input Amplifier Assembly, A23 to A26 Buffer Amplifiers